PowerScale: Upgrade Prep Failure: CELOG Alerts
Summary: Upgrading Gen 6 node Dual Inline memory module (DIMM) but getting 'Hardware Upgrade Prep Failed'.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
When performing the following command, a CELOG error appears:
powerscale-1# /usr/bin/isi_hwtools/isi_upgrade_hardware --cluster --path /root/cluster_hardware_upgrade.json
Start hardware upgrade using /root/cluster_hardware_upgrade.json
Cluster Upgrade Prep Failure: CELOG Alerts
- Critical events exist on the cluster
Hardware Upgrade Prep FailedCause
An internal OneFS database holds a value preventing the upgrade to proceed.
Resolution
Upgrading to OneFS 9.5+ resolves this issue.
Workaround:
- Issue the following command to clear the database event:
powerscale-1# sqlite3 /ifs/.ifsvar/db/celog/events.db 'delete from events where end_time=0 AND severity=3'
- Retry the original command again:
powerscale-1# /usr/bin/isi_hwtools/isi_upgrade_hardware --cluster --path /root/cluster_hardware_upgrade.json
Start hardware upgrade using /root/cluster_hardware_upgrade.json
Hardware Upgrade Prep Passed