Dell Unity: Asynchronous Replication Session not transferring data (User Correctable)
Zusammenfassung: Asynchronous replication session was created, yet no data is being transferred.
Dieser Artikel gilt für
Dieser Artikel gilt nicht für
Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden.
In diesem Artikel werden nicht alle Produktversionen aufgeführt.
Symptome
- Asynchronous replication session is created but no transfer is in progress.
- Replication Connection is green and verified, no errors.
- Network is good, no bottlenecks or hardware issues.
Ursache
- Dell Unity™ Family Security Configuration Guide mentions that the port 8888 is required for an Asynchronous replication. Ports 443/5085 are used for management or for interconnects between arrays and the data transfer is through 8888. If the system detects a valid management path it shows the connection as healthy even though the data path (8888) is blocked.
Lösung
- Make sure port 8888 is allowed between Asynchronous replication interfaces/IPs.
Betroffene Produkte
Dell EMC UnityArtikeleigenschaften
Artikelnummer: 000203359
Artikeltyp: Solution
Zuletzt geändert: 12 Dez. 2025
Version: 4
Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
Support Services
Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.