DSA-2025-297: Security Update for Dell PowerEdge Server for Intel 2025 Security Advisories (2025.3 IPU)

Zusammenfassung: Dell PowerEdge Server remediation is available for 2025.3 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.

Dieser Artikel gilt für Dieser Artikel gilt nicht für Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden. In diesem Artikel werden nicht alle Produktversionen aufgeführt.

Auswirkungen

High

Details

Third-party Component

CVEs

More Information

Intel® Chipset Firmware

CVE-2025-20067

INTEL-SA-01280This hyperlink is taking you to a website outside of Dell Technologies.

Intel® TDX Module

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

INTEL-SA-01312This hyperlink is taking you to a website outside of Dell Technologies.

Intel® Xeon® Processor Firmware

CVE-2025-20053, CVE-2025-21090, CVE-2025-24305

INTEL-SA-01313This hyperlink is taking you to a website outside of Dell Technologies.

 

Dell Technologies empfiehlt allen Kunden, sowohl die CVSS-Gesamtbewertung als auch alle relevanten zeitlichen und umweltbezogenen Bewertungen zu berücksichtigen, die sich auf den potenziellen Schweregrad einer bestimmten Sicherheitsschwachstelle auswirken können.

Betroffene Produkte und Korrektur

CVEs Addressed

Product

Software/Firmware

Affected Versions

Remediated Versions

Link

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R770

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r770/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R670

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r670/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R570

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r570/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R470

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r470/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge XE7740

BIOS

Versions prior to 1.2.2

Version 1.2.2 or later

https://www.dell.com/support/product-details/product/poweredge-xe7740/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R660

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r660/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge C6620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-c6620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge MX760c

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-mx760c/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R860

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r860/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R960

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r960/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge HS5610

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-hs5610/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge HS5620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-hs5620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R660xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r660xs/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xs/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xd2

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xd2/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge T560

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-t560/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xa

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xa/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9680

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe9680/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9680L

BIOS

Versions prior to 2.7.2

Version 2.7.2 or later

https://www.dell.com/support/product-details/product/poweredge-xe9680l/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR5610

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr5610/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR8610t

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr8610t/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR8620t

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr8620t/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR7620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr7620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE8640

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe8640/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9640

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe9640/drivers

CVE-2025-20067

PowerEdge R650

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r650/drivers 

CVE-2025-20067

PowerEdge R750

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750/drivers 

CVE-2025-20067

PowerEdge R750XA

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750xa/drivers 

CVE-2025-20067

PowerEdge C6520

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-c6520/drivers 

CVE-2025-20067

PowerEdge MX750C

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-mx750c/drivers 

CVE-2025-20067

PowerEdge R550

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r550/drivers 

CVE-2025-20067

PowerEdge R450

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r450/drivers 

CVE-2025-20067

PowerEdge R650XS

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r650xs/drivers 

CVE-2025-20067

PowerEdge R750XS

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750xs/drivers 

CVE-2025-20067

PowerEdge T550

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-t550/drivers 

CVE-2025-20067

PowerEdge XR11

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr11/drivers 

CVE-2025-20067

PowerEdge XR12

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr12/drivers 

CVE-2025-20067

PowerEdge T140

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-t140/drivers 

CVE-2025-20067

PowerEdge T340

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-t340/drivers 

CVE-2025-20067

PowerEdge R240

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-r240/drivers 

CVE-2025-20067

PowerEdge R340

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-r340/drivers 

CVE-2025-20067

Dell EMC NX440

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/storage-nx440/drivers 

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

Dell XC Core XC660

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc660-core/drivers

CVE-2025-20053, CVE-2025-24305, CVE-2025-21090

Dell XC Core XC760

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc760-core/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

Dell XC Core XC660xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc660xs-core/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096,CVE-2025-20053, CVE-2025-24305, CVE-2025-21090

Dell XC Core XC760xa

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc760xa-core/drivers

CVE-2025-20067

Dell EMC XC Core XC450

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc450/drivers 

CVE-2025-20067

Dell EMC XC Core XC650

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc650/drivers 

CVE-2025-20067

Dell EMC XC Core XC750

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc750/drivers 

CVE-2025-20067

Dell EMC XC Core XC750xa

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc750-xa/drivers 

CVE-2025-20067

Dell EMC XC Core XC6520

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc6520/drivers 

 

CVEs Addressed

Product

Software/Firmware

Affected Versions

Remediated Versions

Link

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R770

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r770/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R670

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r670/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R570

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r570/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge R470

BIOS

Versions prior to 1.3.2

Version 1.3.2 or later

https://www.dell.com/support/product-details/product/poweredge-r470/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096, CVE-2025-20053, CVE-2025-21090

PowerEdge XE7740

BIOS

Versions prior to 1.2.2

Version 1.2.2 or later

https://www.dell.com/support/product-details/product/poweredge-xe7740/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R660

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r660/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge C6620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-c6620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge MX760c

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-mx760c/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R860

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r860/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R960

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r960/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge HS5610

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-hs5610/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge HS5620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-hs5620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R660xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r660xs/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xs/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xd2

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xd2/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge T560

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-t560/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge R760xa

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-r760xa/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9680

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe9680/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9680L

BIOS

Versions prior to 2.7.2

Version 2.7.2 or later

https://www.dell.com/support/product-details/product/poweredge-xe9680l/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR5610

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr5610/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR8610t

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr8610t/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR8620t

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr8620t/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XR7620

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr7620/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE8640

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe8640/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

PowerEdge XE9640

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/home/product-support/product/poweredge-xe9640/drivers

CVE-2025-20067

PowerEdge R650

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r650/drivers 

CVE-2025-20067

PowerEdge R750

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750/drivers 

CVE-2025-20067

PowerEdge R750XA

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750xa/drivers 

CVE-2025-20067

PowerEdge C6520

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-c6520/drivers 

CVE-2025-20067

PowerEdge MX750C

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-mx750c/drivers 

CVE-2025-20067

PowerEdge R550

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r550/drivers 

CVE-2025-20067

PowerEdge R450

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r450/drivers 

CVE-2025-20067

PowerEdge R650XS

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r650xs/drivers 

CVE-2025-20067

PowerEdge R750XS

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-r750xs/drivers 

CVE-2025-20067

PowerEdge T550

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-t550/drivers 

CVE-2025-20067

PowerEdge XR11

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr11/drivers 

CVE-2025-20067

PowerEdge XR12

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/poweredge-xr12/drivers 

CVE-2025-20067

PowerEdge T140

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-t140/drivers 

CVE-2025-20067

PowerEdge T340

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-t340/drivers 

CVE-2025-20067

PowerEdge R240

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-r240/drivers 

CVE-2025-20067

PowerEdge R340

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/poweredge-r340/drivers 

CVE-2025-20067

Dell EMC NX440

BIOS

Versions prior to 2.20.0

Version 2.20.0 or later

https://www.dell.com/support/home/product-support/product/storage-nx440/drivers 

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

Dell XC Core XC660

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc660-core/drivers

CVE-2025-20053, CVE-2025-24305, CVE-2025-21090

Dell XC Core XC760

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc760-core/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096

Dell XC Core XC660xs

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc660xs-core/drivers

CVE-2025-20613, CVE-2025-22853, CVE-2025-21096,CVE-2025-20053, CVE-2025-24305, CVE-2025-21090

Dell XC Core XC760xa

BIOS

Versions prior to 2.7.5

Version 2.7.5 or later

https://www.dell.com/support/product-details/product/dell-xc760xa-core/drivers

CVE-2025-20067

Dell EMC XC Core XC450

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc450/drivers 

CVE-2025-20067

Dell EMC XC Core XC650

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc650/drivers 

CVE-2025-20067

Dell EMC XC Core XC750

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc750/drivers 

CVE-2025-20067

Dell EMC XC Core XC750xa

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc750-xa/drivers 

CVE-2025-20067

Dell EMC XC Core XC6520

BIOS

Versions prior to 1.18.1

Version 1.18.1 or later

https://www.dell.com/support/home/product-support/product/dell-emc-xc6520/drivers 

 

The Affected Products and Remediation table above may not be a comprehensive list of all affected supported versions and may be updated as more information becomes available.

Revisionsverlauf

Revision

Date

Description

1.0

2025-09-03

Initial release

2.0

2025-09-16

Updating formatting, no new information

 

Zugehörige Informationen

Betroffene Produkte

Dell EMC XC Core XC450, Dell EMC XC Core XC650, Dell EMC XC Core XC6520, Dell EMC XC Core XC750, Dell EMC XC Core XC750xa, Dell XC Core XC660, Dell XC Core XC660xs, Dell XC Core XC760, Dell XC Core XC760xa, PowerEdge C6520, PowerEdge C6620 , PowerEdge HS5610, PowerEdge HS5620, PowerEdge MX750c, PowerEdge MX760c, PowerEdge R240, PowerEdge R340, PowerEdge R450, PowerEdge R470, PowerEdge R550, PowerEdge R570, PowerEdge R650, PowerEdge R650xs, PowerEdge R660, PowerEdge R660xs, PowerEdge R670, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R770, PowerEdge R860, PowerEdge R960, PowerEdge T140, PowerEdge T340, PowerEdge T550, PowerEdge T560, PowerEdge XE7740, PowerEdge XE8640, PowerEdge XE9640, PowerEdge XE9680, PowerEdge XE9680L, PowerEdge XR11, PowerEdge XR12, PowerEdge XR5610, PowerEdge XR7620, PowerEdge XR8610t, PowerEdge XR8620t, Dell EMC NX440 ...
Artikeleigenschaften
Artikelnummer: 000364913
Artikeltyp: Dell Security Advisory
Zuletzt geändert: 16 Sept. 2025
Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
Support Services
Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.