Data Domain: RPM Upload Failure on GUI Exception error occurred
Zusammenfassung: The GUI becomes unresponsive and RPM uploads fail because the iDRAC does not supply Secure Boot entries in host_bios.json, causing the sms_system_get_secure_boot API to error.
Dieser Artikel gilt für
Dieser Artikel gilt nicht für
Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden.
In diesem Artikel werden nicht alle Produktversionen aufgeführt.
Symptome
Observed Symptoms
- Data Domain Web GUI is extremely slow or unresponsive.
- RPM package upload via the GUI fails after showing 95% progress. Error "There was an exception retrieving data. Please view your log files"
- Navigating to the Maintenance -> System page throws below error
- Log entry:
09 Jan 2026 11:49:59,972 ERROR [xxx-xxx-127.0.0.1-8009-exec-563] An exception occurred while handling a client request com.datadomain.webf.shared.sms.SMException:
- Backend logs show
ERROR: pta_json_get_specific_obj: error parsing JSON object SecureBoot ERROR: pta_json_file_get_object: failed to get JSON object value ERROR: plat_pta_secure_boot_get_status: Secure Boot: failed to get object "SecureBoot" ERROR: Failed to get Secure Boot status, rc = 8
Ursache
Root Cause Analysis
The Data Domain Web GUI becomes unresponsive and RPM uploads fail because the host_bios.json file retrieved from the iDRAC does not contain the required Secure Boot fields. The missing fields cause the sms_system_get_secure_boot API call to throw exceptions, preventing the GUI from completing the upload workflow.
Contributing Factors
- The DDOS component relies on the HOSA REST API to obtain Secure Boot status; without the JSON entries, the API returns an I/O error.
- Resulting error propagates to the web server, leading to the observed “Exception error occurred” message
Lösung
Resolution Steps
- Reset the iDRAC to restore proper BIOS JSON provisioning.
- Verify GUI responsiveness and retry the RPM upload via the GUI
- If the issue persists, collect System Update Package (SUB) logs for deeper analysis and contact Dell Support.
Betroffene Produkte
Data DomainArtikeleigenschaften
Artikelnummer: 000496707
Artikeltyp: Solution
Zuletzt geändert: 07 Aug. 2026
Version: 1
Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
Support Services
Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.