Isilon:節點韌體更新發生錯誤,包括:InstallFirmware 命令的例外狀況:[埃爾諾 54]RPC 工作階段已中斷連線。

Summary: 在 Isilon 節點的韌體升級期間,InstallFirmware 作業會中止,並記錄由遠端程序呼叫 (RPC) 工作階段中斷連線所導致的 IOError Errno 54。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



執行節點韌體更新時,更新會在節點上發生錯誤。

使用 isi_upgrade_logs 收集升級錯誤,發現下列錯誤訊息:
Starting /usr/sbin/isi_Upgrade_Agent.py InstallFirmware

2018-10-10 10:10:10,101 DEBUG Execute Command: InstallFirmware
2018-10-10 10:10:10,101 ERROR Exception for InstallFirmware command: [Errno 54] RPC session disconnected.



其他案例報告了類似以下情況的額外輸出:

2019-01-01 12:00:00,000 DEBUG Execute Command: InstallFirmware
2019-01-01 12:00:00,000 ERROR Exception for InstallFirmware command:

Devid 1:
Traceback (most recent call last):
  File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 698, in rpcCaller
  File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 149, in __call__
  File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 512, in _request
  File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 122, in wait
  File "/usr/local/lib/python2.7/site-packages/isi/net/session.py", line 137, in wait
IOError: [Errno 54] RPC session disconnected.

Cause

Resolution

在發生錯誤的節點上重試最後一個動作,方法是執行下列命令,將 LNN 更換為節點編號:
isi upgrade cluster retry-last-action LNN

After performing a retry, wait for a few minutes for the firmware updates to resume, if the error message returns a second time, escalation to Isilon support for further investigation.

Affected Products

Isilon

Products

Isilon, PowerScale OneFS
Article Properties
Article Number: 000167758
Article Type: Solution
Last Modified: 05 May 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.