Isilon:节点固件更新错误:InstallFirmware 命令的例外:[提供编号 54]RPC 会话已断开连接。
Summary: 在 Isilon 节点上,在固件升级期间,InstallFirmware作中止,并记录由远程过程调用 (RPC) 会话断开导致的 IOError 错误 54。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
执行节点固件更新时,更新在节点上遇到错误。
使用isi_upgrade_logs收集升级错误时,会发现以下错误消息:
Starting /usr/sbin/isi_Upgrade_Agent.py InstallFirmware 2018-10-10 10:10:10,101 DEBUG Execute Command: InstallFirmware 2018-10-10 10:10:10,101 ERROR Exception for InstallFirmware command: [Errno 54] RPC session disconnected.
其他案例报告了类似于以下内容的额外输出:
2019-01-01 12:00:00,000 DEBUG Execute Command: InstallFirmware 2019-01-01 12:00:00,000 ERROR Exception for InstallFirmware command: Devid 1: Traceback (most recent call last): File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 698, in rpcCaller File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 149, in __call__ File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 512, in _request File "/usr/local/lib/python2.7/site-packages/isi/net/rpc.py", line 122, in wait File "/usr/local/lib/python2.7/site-packages/isi/net/session.py", line 137, in wait IOError: [Errno 54] RPC session disconnected.
Cause
。
Resolution
通过运行以下命令将 LNN 替换为节点编号,在遇到错误的节点上重试上次作:
isi upgrade cluster retry-last-action LNN
After performing a retry, wait for a few minutes for the firmware updates to resume, if the error message returns a second time, escalation to Isilon support for further investigation.