Резервне копіювання NMDA Informix dbspace не працює
Помилка в bar_act.log

 Archive on rootdbs, datadbs, datadbs1, idx16kdbs1, datadbs3, calldbs1, idxdbs1, datadbs6, datadbs2, datadbs7, datadbs5, datadbs4, datadbs8, sbdbs1, tempdbs4, tempdbs, llogdbs, plogdbs1 ABORTED (Requested Level 0).
/home/informix/bin/onbar_d complete, returning 3 (0x03)
 XBSA Error: (BSAEndTxn) A system error occurred. Aborting XBSA session.

 Помилка з libnsrifmx Журнал

nwbsa_close_saveset_session: received a network error (Severity 5 Number 22): Setting of retention lock for file '<filename>' failed 
ddp_set_retention_time() failed, su_name=, path_name=<path to file/filename >, Err: 5955-nfs setattr failed (nfs: Illegal minimum retention time)

Cause

Налаштування блокування утримання властивостей пристрою NetWorker знаходиться поза часом утримання, встановленим у Data Domain.

Resolution

Налаштуйте налаштування блокування утримання в Data Domain, щоб врахувати період блокування утримання, встановлений у NetWorker.
Цю команду можна використовувати в системі домену даних.

  1. Відкрийте SSH-сесію в домені даних. Увійдіть як системний адміністратор.
  2. Отримайте шлях mtree сервера NetWorker:
# mtree list
  1. Відкоригуйте мінімальні та максимальні періоди блокування mtree.
# mtree retention-lock set min-retention-period [period] mtree [mtree]
# mtree retention-lock set max-retention-period [period] mtree [mtree]

Additional Information