Article Number: 000130128
Severity |
Error message |
Cause |
Critical |
CMC <number> Battery: Battery sensor for CMC, failed was asserted |
CMC CMOS battery is missing or has no voltage. |
Critical |
CMC <number> CPU Temp: Temperature sensor for CMC, failure event |
CMC CPU temperature has exceeded the critical threshold. |
Critical |
CMC <number> Ambient Temp: Temperature sensor for CMC, failure event |
CMC ambient temperature has exceeded the critical threshold. |
Severity |
Error message |
Cause |
Critical |
Chassis Fan <number> presence: Fan sensor for Chassis Fan, device removed was asserted |
The removed fan is required for proper cooling of the enclosure/chassis. |
Critical |
Power Supply Redundancy: PS Redundancy sensor for Power Supply, redundancy lost was asserted |
One or more power supply units (PSUs) has failed or been removed so the system is no longer redundant. |
Critical |
Power Supply Redundancy: PS Redundancy sensor for Power Supply, non-redundant: insufficient resources |
One or more PSU has failed or been removed and the system lacks enough power to maintain normal operations. Servers could power down. |
Critical |
Control Panel Temp: Temperature sensor for Control Panel, failure event |
The Chassis/Enclosure temperature exceeded the critical threshold. |
Critical |
CMC<number>Stand-alone: Micro Controller sensor for CMC, non-redundant was asserted |
The CMC is no longer redundant. This message will only show if the standby CMC was removed or failed. |
Critical |
Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, all event logging disabled was asserted |
The CMC cannot log events when the Event Log sensor is disabled. The Event Log is disabled when it becomes full. Clearing the log re-enables event logging. |
Critical |
Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, log full was asserted |
The chassis device detects that only one entry can be added to the CEL before it is full. |
Warning |
Chassis Eventlog CEL: Event Log sensor for Chassis Eventlog, log almost full was asserted |
The chassis event log is 75% full. |
Warning |
Power Supply Redundancy: PS Redundancy sensor for Power Supply, redundancy degraded was asserted |
One or more PSU has failed or been removed and the system can no longer support full PSU redundancy. |
Severity |
Error message |
Cause |
Critical |
Chassis Fan <number> Status: Fan sensor for Chassis Fan, failure event |
The speed of the specified fan is not sufficient to provide enough cooling to the system. |
Severity |
Error message |
Cause |
Critical |
I/O Module <number> Status: Module sensor for I/O Module, transition to critical from less severe was asserted |
The I/O module has a fault. The same error can also happen if the I/O module is thermal-tripped. |
Warning |
I/O Module <number> Status: Module sensor for I/O Module, transition to non-critical from OK was asserted |
The IO module has a fabric mismatch or a link tuning mismatch. |
Severity |
Error message |
Cause |
Non-Recoverable |
Local KVM Health: Module sensor for Local KVM, transition to non-recoverable was asserted |
The Serial RIP or USB host chip has failed.
|
Critical |
Local KVM Health: Module sensor for Local KVM, transition to critical from less severe was asserted |
The USB host enumeration or OSCAR failure has failed. |
Warning |
Local KVM Health: Module sensor for Local KVM, transition to non-critical from OK was asserted |
There has been a minor failure, such as corrupted firmware. |
Severity |
Message |
Cause |
Critical |
Power Supply PSU <number>: Power Supply sensor for Power Supply, failure was asserted |
The PSU has failed. |
Critical |
Power Supply PSU <number>: Power Supply sensor for Power Supply, input lost was asserted |
The AC power cord has been unplugged or there has been a loss of AC power. |
Severity |
Error message |
Cause |
Warning |
System Board Ambient Temp: Temperature sensor for System Board, warning event |
The server ambient temperature crossed a warning threshold. |
Critical |
System Board Ambient Temp: Temperature sensor for System Board, failure event
|
The server ambient temperature crossed a failing threshold. |
Critical |
System Board CMOS Battery: Battery sensor for System Board, failed was asserted |
The CMOS battery is not present or has no voltage.
|
Warning |
System Board Current Monitor: Current sensor for System Board, warning event
|
The current crossed a warning threshold. |
Critical |
System Board Current Monitor: Current sensor for System Board, failure event |
The current has crossed a failing threshold. |
Critical |
<voltage sensor name>: Voltage sensor for System Board, state asserted was asserted |
The voltage is out of range. |
Critical |
CPU<number> Status: Processor sensor for CPU<number, IERR was asserted
|
The CPU has failed. |
Critical |
CPU<number> Status: Processor sensor for CPU<number>, thermal tripped was asserted |
The CPU has overheated. |
Critical |
CPU<number> Status: Processor sensor for CPU<number, configuration error was asserted |
The processor is the incorrect type or in the wrong location. |
Critical |
CPU<number> Status: Processor sensor for CPU<number>, presence was deasserted |
The required CPU is missing or not present. |
Critical |
System Board Video Riser: Module sensor for System Board, device removed was asserted |
The required module was removed.
|
Critical |
Mezz B Status: Add-in Card sensor for Mezz B, install error was asserted |
The incorrect Mezzanine card is installed for I/O fabric. |
Critical |
Mezz C Status: Add-in Card sensor for Mezz C, install error was asserted |
The incorrect Mezzanine card was installed for I/O fabric. |
Critical |
Backplane Drive <number>: Drive Slot sensor for Backplane, drive removed |
The storage drive was removed. |
Critical |
Backplane Drive <number>: Drive Slot sensor for Backplane, drive fault was asserted |
The storage drive failed. |
Critical |
System Board PFault Fail Safe: Voltage sensor for System Board, state asserted was asserted |
This event is generated when the system board voltages are not at normal levels. |
Critical |
System Board OS Watchdog: Watchdog sensor for System Board, reboot was asserted |
The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from host) and the action is set to reboot. |
Critical |
System Board OS Watchdog: Watchdog sensor for System Board, power off was asserted |
The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from host) and the action is set to power off. |
Critical |
System Board OS Watchdog: Watchdog sensor for System Board, power cycle was asserted |
The iDRAC watchdog detected that the system has crashed (the timer expired because no response was received from Host) and the action is set to power cycle. |
Critical |
System Board SEL: Event Log sensor for System Board, log full was asserted |
The SEL device has detected that only one entry can be added to the SEL before it is full. |
Warning |
ECC Corr Err: Memory sensor, correctable ECC ( <DIMM Location> ) was asserted |
Correctable ECC errors have reached a critical rate. |
Critical |
ECC Uncorr Err: Memory sensor, uncorrectable ECC ( <DIMM Location> ) was asserted |
An uncorrectable ECC error was detected. |
Critical |
I/O Channel Chk: Critical Event sensor, I/O channel check NMI was asserted |
A critical interrupt has been generated in the I/O Channel. |
Critical |
PCI Parity Err: Critical Event sensor, PCI PERR was asserted |
A parity error was detected on the PCI bus. |
Critical |
PCI System Err: Critical Event sensor, PCI SERR ( <Slot number or PCI Device ID>) was asserted |
The device detected a PCI error. |
Critical |
SBE Log Disabled: Event Log sensor, correctable memory error logging disabled was asserted |
Single-bit error logging is disabled when too many SBEs are logged. |
Critical |
Logging Disabled: Event Log sensor, all event logging disabled was asserted |
All error logging is disabled. |
Non-Recoverable |
CPU Protocol Err: Processor sensor, transition to non-recoverable was asserted |
The processor protocol has entered a nonrecoverable state. |
Non-Recoverable |
CPU Bus PERR: Processor sensor, transition to non-recoverable was asserted |
The processor bus PERR has entered a nonrecoverable state. |
Non-Recoverable |
CPU Init Err: Processor sensor, transition to non-recoverable was asserted |
The processor initialization has entered a nonrecoverable state. |
Non-Recoverable |
CPU Machine Chk: Processor sensor, transition to non-recoverable was asserted |
The processor machine check has entered a nonrecoverable state. |
Critical |
Memory Spared: Memory sensor, redundancy lost (<DIMM Location> ) was asserted |
Memory spare is no longer redundant. |
Critical |
Memory Mirrored: Memory sensor, redundancy lost (<DIMM Location> ) was asserted |
The mirrored memory is no longer redundant. |
Critical |
Memory RAID: Memory sensor, redundancy lost (<DIMM Location> ) was asserted |
The RAID memory is no longer redundant. |
Critical |
Memory Cfg Err: Memory sensor, configuration error (<DIMM Location> ) was asserted |
The memory configuration is incorrect for the system. |
Warning |
Mem Redun Gain: Memory sensor, redundancy degraded (<DIMM Location> ) was asserted |
The memory redundancy is downgraded but not lost. |
Critical |
PCIE Fatal Err: Critical Event sensor, bus fatal error was asserted |
A fatal error is detected on the PCI bus. |
Critical |
Chipset Err: Critical Event sensor, PCI PERR was asserted |
A chip error is detected. |
Warning |
Mem ECC Warning: Memory sensor, transition to non-critical from OK (<DIMM Location> ) was asserted |
Correctable ECC errors have surpassed a normal rate. |
Critical |
Mem ECC Warning: Memory sensor, transition to critical from less severe ( <DIMM Location> ) was asserted |
Correctable ECC errors have reached a critical rate. |
Critical |
System Board POST Err: POST sensor for System Board, POST fatal error <additional error information> was asserted |
See the Dell PowerEdge M1000e EnclosureOwner’s Manual for additional error information on BIOS POST errors. |
PowerEdge M1000E
06 Apr 2021
4
Solution