VNX: Control Station shows "Security file not found. Already removed or check -secfilepath option"

Summary: CS is showing: Security file not found. Already removed or check -secfilepath option. and getting the message A library or configuration file for NaviSECCli is missing or corrupt. (User Correctable) ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Upgraded from previous version and Security file has not been updated with correct credentials for the Storage System.
 

./naviseccli -User nasadmin -Password nasadmin -h  name-spa -Scope 0 security -certificate -setlevel low
Error occurred while trying to connect: 'name-spa'.
Message : A library or configuration file for NaviSECCli is missing or corrupt. Please use command "security -certificate -cleanup" to fix it.
Control Station shows "Security file not found.  Already removed or check -secfilepath option." when running naviseccli commands.

Cause

Upgraded from previous version and Security file has not been updated with correct credentials for the Storage System.

Resolution

To update the security file with the correct need to run following command from the Control Station CLI.

Adding sysadmin to the security file with default password and as a global account.

  $/nas/sbin/naviseccli -AddUserSecurity -scope 0 -password sysadmin -user sysadmin

Affected Products

VNX1 Series

Products

VNX1 Series, VNX2 Series
Article Properties
Article Number: 000056810
Article Type: Solution
Last Modified: 11 Nov 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.