GDDR: Opgradering til z/OS 2.5 får abends og GDDR Control SYSTEMS til at køre i forringet tilstand
Summary: Opgradering til z/OS 2.5 medfører afvigelser i geografisk spredt genstart efter nedbrud (GDDR), og GDDR Control SYSTEMS (C-SYS) kører i forringet tilstand.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Mainframe-operativsystemets software opdateres til z/OS 2.5-softwareniveau med vedligeholdelsestolerance. z/OS 2.5 bruges til en ny IBM z16-CPU.
GDDR GDDRMAIN startede op med flere ABEND'er, efter at z/OS-vedligeholdelsen blev anvendt:
- HBM rapporterer nedenstående fejl ved GDDRMAIN-opstart, GDDR-værten er i forringet tilstand:
ABEND S0E0-29
- GDDRRPT rapporterer nedenstående fejl ved GDDRMAIN-nedlukning:
ABEND S0E0-28
Følgende fejlmeddelelser sendes i GDDR Event Monitor (EVM) og Heartbeat Monitor (HBM) output:
GDDUG86E No matching GDDR systems found
Hvis ABEND S0E0-28 forekommer ved GDDRMAIN-nedlukning, derefter en Abend S067-04 kan forekomme, hvis GDDRMAIN bringes op igen.
Cause
En
Derudover har en
ABEND S0E0-29 kan forekomme ved GDDRMAIN-start i HBM-underopgaven på modul GDDREVMI, offset 0005AF74.
PSW 183158F0 0010D507 3000F154Dette får HBM-underopgaven til at afslutte og efterlader GDDRMAIN uden funktioner til overvågning af hjerteslag. GDDR-værten kører i forringet tilstand. GDDREVMI opdateres for at rydde REGISTRER AR15, før du bruger registret for at undgå en
ABEND S0E0-29.
Derudover har en
ABEND S0E0-28 kan forekomme i GDDRRPT ved GDDRMAIN-nedlukning ved GDDRMAIN, forskydning 0006EAB2.
PSW D24FD37A 1000D207 D37D5004GDDRRPT opdateres for at rydde REGISTRER AR1 for at undgå en
ABEND S0E0-28. GDDRMAIN opdateres for at kontrollere, at ALET (Access List Entry Token) er gyldig i dataområde 2. Denne handling udføres, før du får adgang til dataområdet for en anden GDDR-forekomst. Denne handling hjælper med at undgå en Abend S067-04 i GDDRMAIN-opstarten på grund af en anden GDDR-forekomst, der ikke lukker rent ned.Resolution
Løsning:
- Ingen til ABEND S0E0-29, men GDDR-værterne fortsætter med at køre i forringet tilstand.
- Der kræves en indledende programbelastning (IPL) af den logiske partition (LPAR) for at rydde hukommelsen, hvis en
Abend S067-04Opstår.
Permanent løsning:
- Til GDDR 6.0 kan PTF-GD60004 (Program Temporary Fix) og GD60005 downloades fra Dell Support.
- For GDDR 6.1 løses problemet i basisproduktet. Den kan downloades fra Dell Support.
Additional Information
Beskrivelse af programmidlertidig rettelse (PTF) –
++PTF(GD60004) REWORK(2022315) .
++VER(Z038) FMID(GDDR600)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3459
* USERS AFFECTED: GDDR users
* PROBLEM DESCRIPTION: Warning message GDDUG24W results in
* RC 8 on pre-script and post-script
* configuration displays
*
* DESCRIPTION DETAIL:
*
* During GDDR scripts, warning message GDDUG24W could result
* in an RC 8 on the pre-script and post-script configuration
* displays, for example:
*
* GDDUG24W 2 external RDF groups indicate SRDF/A active
* GDDR639I GDDR Completed pre-script configuration display
* with rc 8
*
* This is simply a messaging issue, as a non-zero RC on the
* configuration displays does not affect the outcome of the
* script.
*
* PROBLEM RESOLUTION:
*
* Warning message GDDUG24W will now result in an RC 4 on the
* configuration displays, as expected.
*
* MODULES: GDDRMCMD
*
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3460 GDDR-3472
* USERS AFFECTED: GDDR users
* PROBLEM DESCRIPTION: ABENDS067-04 upon GDDRMAIN startup due
* to another GDDR instance not shutting
* down cleanly
*
* DESCRIPTION DETAIL:
*
* An S067-04 abend could occur upon GDDRMAIN startup at
* GDDRMAIN offset 000006AC (data at PSW 4038B219 02009540
* 50E8B219) if another GDDR instance was not shut down
* cleanly. This causes GDDRMAIN to terminate.
*
* PROBLEM RESOLUTION:
*
* An S067-04 abend should no longer occur upon GDDRMAIN
* startup if another GDDR instance was not shut down cleanly.
*
* In addition, the GDDRMAIN ESTAE routine has been improved to
* ensure that GDDRMAIN is shut down cleanly in case of an
* abend.
*
* MODULES: GDDRMAIN
* GDDRMCMD
*
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3499
* USERS AFFECTED: GDDR users
* PROBLEM DESCRIPTION: New PRIMARY command to display primary
* C-system name
*
* DESCRIPTION DETAIL:
*
* A new command is needed to display the primary C-system name
* from any system in the GDDR-plex, including managed systems.
*
* PROBLEM RESOLUTION:
*
* A new PRIMARY command has been created to display the
* primary C-system name from the point-of-view of one or more
* C-systems. By default, the point-of-view from all C-systems
* is shown. The SYSTEM parameter may be used to narrow the
* scope to the specified C-system, and the SITE parameter may
* be used to narrow the scope to the C-system at the specified
* site. This command may be issued from any system where
* GDDRMAIN is active, including managed systems. It can be
* issued as a GDDRMAIN modify command (e.g., F GDDRMAIN,PRI),
* as a Perform Health Check panel primary command (e.g., PRI),
* or using the GDDRMCMD batch interface (see GDDRMCMD in
* SAMPLIB).
*
* Syntax:
*
* PRImary
* [,SITE={DC1|DC2|DC3|DC4}]
* [,SYStem={<system_name>|LoCaL|ALL}]
* [,TiMeOut=<seconds>]
* [,CONsole[={Yes|No}]]
* [,SysMSG[={Yes|No}]]
* [,SysPRinT[={Yes|No}]]
* [,DeBuG[={Yes|No}]]
*
* Example:
*
* GDDUC04I Primary C-system as seen from the indicated
* site/system
* ---------------------------------------------------------
* Site System Value
* ---- -------- -----------------------------------------
* DC1 N247 N247
* DC2 X99 N247
* DC3 X98 N247
* ---------------------------------------------------------
*
* MODULES: GDDRMCMD
* GDDRMCON
*
* ------------------------------------------------------------
++PTF(GD60005) REWORK(2023012) .
++VER(Z038) FMID(GDDR600)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3463 GDDR-3465
* USERS AFFECTED: GDDR users
* PROBLEM DESCRIPTION: ABENDS0E0-29 upon GDDRMAIN startup or
* ABENDS0E0-28 upon GDDRMAIN shutdown
*
* DESCRIPTION DETAIL:
*
* An S0E0-29 abend could occur upon GDDRMAIN startup in the
* HBM (heartbeat monitor) subtask at GDDREVMI offset 0005AF74
* (data at PSW 183158F0 0010D507 3000F154). This causes the
* HBM subtask to terminate and leaves GDDRMAIN without
* heartbeat monitoring capabilities.
*
* In addition, an S0E0-28 abend could occur in GDDRRPT upon
* GDDRMAIN shutdown at GDDRMAIN offset 0006EAB2 (data at PSW
* D24FD37A 1000D207 D37D5004).
*
* PROBLEM RESOLUTION:
*
* An S0E0 abend should no longer occur upon GDDRMAIN startup
* in GDDREVMI or upon GDDRMAIN shutdown in GDDRRPT.
*
* MODULES: GDDREVMI
* GDDRRPT
Affected Products
Geographically Dispersed Disaster Restart (GDDR)Article Properties
Article Number: 000203766
Article Type: Solution
Last Modified: 07 Aug 2025
Version: 3