GDDR: ABENDs 0C4-04 e 0C4-10 e mensagem de erro GDDM105E ocorrendo

Summary: ABENDS 0C4-04 e 0C4-10 estão ocorrendo em GDDRMAIN em DC1 e DC2. A mensagem de erro GDDM105E ocorre após ABEND 0C4-10 no DC2. DC2 é o local principal.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

ABENDS 0C4-04 e 0C4-10 estão ocorrendo em GDDRMAIN em DC1 e DC2. A mensagem de erro GDDM105E ocorre após ABEND 0C4-10 no DC2. DC2 é o local principal.

DC1:

IEA794I SVC DUMP HAS CAPTURED:  973                                   
DUMPID=001 REQUESTED BY JOB (GDDRMAIN)                                
DUMP TITLE=GDDRMCMD Abend                                             
IEA995I SYMPTOM DUMP OUTPUT  979                                      
SYSTEM COMPLETION CODE=0C4  REASON CODE=00000004                      
 TIME=12.28.05  SEQ=00055  CPU=0000  ASID=0049                        
 PSW AT TIME OF ERROR  078C2000   9F6518E4  ILC 6  INTC 04            
   ACTIVE MODULE           ADDRESS=00000000_1F600F78  OFFSET=0005096C 
   NAME=GDDRMAIN                                                      
   DATA AT PSW  1F6518DE - D2451001  1000D213  1031DB39               
   GR 0: 1F726FDE   1: 1F726FDE                                       
      2: 1F91B358   3: 009ECD64                                       
      4: 00000000   5: 00F95280                                       
      6: 009D1FC8   7: 00000E00                                       
      8: 1F63DDD8   9: 1F920F8D                                       
      A: 1D898180   B: 1F63D120                                       
      C: 9F622878   D: 1F91FED0                                       
      E: 1F920C57   F: 9F651820                                       
 END OF SYMPTOM DUMP                                                                                

DC2:

IEA995I SYMPTOM DUMP OUTPUT  371                                      
SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010                      
 TIME=13.30.42  SEQ=00050  CPU=0000  ASID=004F                        
 PSW AT TIME OF ERROR  478C0000   9F75BDCC  ILC 4  INTC 10            
   ACTIVE MODULE           ADDRESS=00000000_1F74DC98  OFFSET=0000E134 
   NAME=GDDRWMGR                                                      
   DATA AT PSW  1F75BDC6 - C37858A0  7058BF9F  A0349A0F               
   GR 0: 00000010   1: 1F91E4C0                                       
      2: 1F693238   3: 00000000                                       
      4: 1F91E4C0   5: 1F91E758                                       
      6: 1F91EB48   7: 1F693000                                       
      8: 00000000   9: 00000000                                       
      A: 60606060   B: 00000000                                       
      C: 9F75BBA4   D: 1F6932C8                                       
      E: 00FD6320   F: 9F75BBA4                                       
 END OF SYMPTOM DUMP                

Mensagem de erro DC2:

GDDM105E Unable to obtain work control block

A mensagem de erro ocorrerá horas depois se o WORKMGR for reiniciado. Essa mensagem de erro é postada repetidamente.

Cause

As falhas de S0C4-10 ou S0C4-04 são causadas por uma sobreposição de buffer na área de trabalho do Gerente de trabalho do GDDR (Geographically Dispersed Disaster Restart) (GDDRWMGR). Os Abends podem ocorrer no GDDRMCMD no momento da sobreposição do buffer ou após o fato no GDDRWMGR.

Resolution

Correção permanente: Para GDDR 6.0, o GD60020 PTF (Program Temporary Fix, Correção Temporária do Programa) está disponível para resolver o problema. Ele está disponível para download no Suporte on-line da Dell.

Affected Products

Geographically Dispersed Disaster Restart (GDDR)
Article Properties
Article Number: 000218044
Article Type: Solution
Last Modified: 07 Aug 2025
Version:  3
Find answers to your questions from other Dell users