NMDA:DB2 备份失败 错误 _nwbsa_senddata32:系统检测到错误,原因是:发送数据缓冲区。操作已中止

Summary: NetWorker Module for Database Applications (NMDA) DB2 备份失败,错误 nwbsa_senddata32:系统检测到错误,原因是:发送数据缓冲区。操作已中止

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

错误输入 db2diag.log

NMDA DB2 backup fails Error _nwbsa_senddata32: System detected error due to: sending a data buffer. Operation aborted

NMDA 中的错误 /app/log/

DB2 Backup Hung with error: Unable to backup BIP database due to backup request failure, SQLCODE : -2025, SQL2025N An I/O error occurred. Error code: "3".

Cause

DB2 缓冲区大小太小。

Resolution

  1. 调整 DB2_BUFFER_SIZE 按照NetWorker Module for Database and Applications Administration Guide中的说明进行操作。NMDA 文档可通过以下方式获得:适用于NetWorker Module for Databases and Applications的支持 |手册和文档 
    提醒:对于计划备份,您可以设置 DB2_BUFFER_SIZE 参数,如 DB2 缓冲区大小 一节中所述。
  2. 如何从 IBM DB2 调优 DB2 缓冲池大小 手册:设置 DB2 缓冲池大小 - IBM 文档 本超链接将引导您访问非 Dell Technologies 运营的网站。

Affected Products

NetWorker, NetWorker Module for Databases and Applications