错误输入 db2diag.log
NMDA DB2 backup fails Error _nwbsa_senddata32: System detected error due to: sending a data buffer. Operation aborted
NMDA 中的错误 /app/log/
DB2 Backup Hung with error: Unable to backup BIP database due to backup request failure, SQLCODE : -2025, SQL2025N An I/O error occurred. Error code: "3".
Cause
DB2 缓冲区大小太小。
Resolution
- 调整
DB2_BUFFER_SIZE按照NetWorker Module for Database and Applications Administration Guide中的说明进行操作。NMDA 文档可通过以下方式获得:适用于NetWorker Module for Databases and Applications的支持 |手册和文档
提醒:对于计划备份,您可以设置DB2_BUFFER_SIZE参数,如 DB2 缓冲区大小 一节中所述。 - 如何从 IBM DB2 调优 DB2 缓冲池大小 手册:设置 DB2 缓冲池大小 - IBM 文档