VxFlex: 14G Ready Node - Spontaneous SDC Disconnects

Summary: ESXi VMkernel log shows that SDC disconnects on 14G Ready Nodes.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

14G Ready Node ESXi SDCs report sockets closed in vmkernel.log, with no network connectivity events present.


Symptoms

Vmkernel.log shows sockets closing from the SDS side:

2018-06-06T12:32:26.751Z cpu18:67023)scini: netSock_RcvIntrn: 1903: ScaleIO R2_5:Error: Failed Connection reset by peer to receive 128 data PTR 0x43099c807194 socket 0x43099c8075b0 2018-06-06T12:32:26.751Z cpu5:66328)scini: netSock_Disconnect_CK: 1062: ScaleIO R2_5:Warning: Error Connection reset by peer to shut down socket 0x43099c828260

 

Impact

None is observed, but in the middle of IO this could potentially impact volume access. 

Cause

BIOS issue

Resolution

Customers must upgrade to BIOS version 1.3.7 or higher.  

 

Additional Information

Impacted versions

14G Ready Nodes (PowerEdge 14G) with BIOS below 1.3.7 


Fixed in version

PowerEdge BIOS 1.3.7+ (BIOS version 1.4.5 included in AMS 2.6, for instance.)

Affected Products

VxFlex Product Family

Products

PowerFlex Software, VxFlex Product Family, VxFlex Ready Node, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R840
Article Properties
Article Number: 000067874
Article Type: Solution
Last Modified: 10 Nov 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.