# | Date | Error Code | Error Message |
---|---|---|---|
1 | 2019-03-19T15:44:52-0500 |
PSU0800 |
Power Supply 2: Status = 0x00, IOUT = 0x0, VOUT= 0x0, TEMP= 0x0, FAN = 0x0, INPUT= 0x0. |
2 | 2019-03-19T15:44:51-0500 |
PSU0800 |
Power Supply 1: Status = 0x00, IOUT = 0x0, VOUT= 0x0, TEMP= 0x0, FAN = 0x0, INPUT= 0x0. |
Lifecycle Controller Logs reporting RAC0182
events due to Watchdog timeout.
# | Date | Error Code | Error Message |
---|---|---|---|
1 | 2019-03-23T15:40:38-0500 |
RAC0182 |
The iDRAC firmware was rebooted with the following reason: watchdog. |
2 | 2019-03-23T15:39:18-0500 |
RAC0708 |
|
On modular platforms, the Chassis Management Controller (CMC) may report various System Health Warnings (SWC8619, CMC8526, CMC8527) from impacted modular blades within Chassis Management Controller Logs.
# | Date | Error Code | Error Message |
---|---|---|---|
1 | Oct 23 01:14:41 |
st-m1000e-01 |
Severity: Warning, Category: Configuration, MessageID: SWC8619, Message: The Chassis Management Controller is unable to process data from the server in slot 1. |
2 | Oct 23 01:15:27 |
st-m1000e-01 |
Severity: Warning, Category: System Health, MessageID: CMC8526, Message: Unable to retrieve the server-1 CPU information. |
3 | Oct 23 01:15:27 |
st-m1000e-01 |
Severity: Warning, Category: System Health, MessageID: CMC8527, Message: Unable to retrieve the server-1 memory information. |
4 | Oct 23 01:32:45 |
st-m1000e-01 |
Severity: Warning, Category: System Health, MessageID: CMC8526, Message: Unable to retrieve the server-1 CPU information. |
5 | Oct 23 01:32:45 |
st-m1000e-01 |
Severity: Warning, Category: System Health, MessageID: CMC8527, Message: Unable to retrieve the server-1 memory information. |
Dell Technologies iDRAC Engineering has identified a memory leak in an iDRAC kernel driver. See the release versions below for applicable fix. It is Dell EMC Engineering's recommendation to apply this urgent update at the earliest available update window.
Early May 2019
)End of May 2019
)
Resetting iDRAC through in-band, out-of-band, or draining flea power will temporarily release the claimed memory space.