Data Domain: STORAGE-00009 | RAID Protection in Critical State

Summary: Data Domain systems initiate a graceful shutdown if multiple disk failures occur and RAID reconstruction cannot proceed. This protective measure prevents potential data loss when RAID protection reaches a critical state. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The STORAGE-00009 alert fires when two or more disks fail and RAID reconstruction cannot proceed, either because no spare disks are available or because reconstruction has stalled.

  • The system generates event code: STORAGE-00009
  • The following alert message appears:
    Two or more disks are failed and the RAID protection is in critical state for over a considerable period of time. 
    If an additional disk fails, there might be permanent loss of data. The system will shut down.
    
  • A RAID6 disk group operates in a degraded state with two failed disks.
  • No spare disks are available to support reconstruction.
  • RAID reconstruction stalls or fails to progress.
  • The system initiates a graceful shutdown to protect data integrity.

Cause

The Data Domain Operating System (DDOS) continuously monitors disk health and RAID status. When two or more disks fail and one of the following conditions exists, DDOS triggers a protective system shutdown:

  • No spare disks are available for RAID reconstruction.
  • RAID reconstruction fails to progress within the monitored time window.

DDOS performs this shutdown to prevent further degradation and potential permanent data loss that would result from an additional disk failure in the already‑critical RAID group.

Known Software/Firmware Causes of Multiple Disk Failures

If multiple disk failures are occurring due to a software or firmware defect rather than physical disk faults, replacing disks alone will not resolve the issue. Check the following articles to determine whether a known root cause applies to your system:

Resolution

Proactive measures to prevent this condition:

  1. Replace failed disks promptly. Each replaced disk becomes an available spare for future RAID reconstruction.
  2. Monitor disk health regularly and do not allow failed disks to accumulate in the system.
  3. Maintain adequate spare disk inventory so that automatic reconstruction can begin immediately after a failure.

Reactive steps when STORAGE-00009 fires:

Step 1 - Assess the current RAID protection state:

    1. Log in to the Data Domain system CLI.
    2. Run the following commands to evaluate disk health and RAID status:
      • # disk show state
      • # disk show failure-history
    3. Count the number of disks in a **Failed** state and identify which disk groups are affected.
    4. Run the following command to confirm whether the STORAGE-00009 alert is active:
      • # alerts show current
    5. Determine the severity of the condition:
      • Condition Risk Level Recommended Action
        STORAGE-00009 alert is active; RAID protection is in critical state Critical — the system may shut down to prevent data loss Contact Dell ProSupport immediately and communicate the critical RAID state
        Multiple failures span different disk groups; spare disks are available
        High - the system is degraded but retains RAID protection
         
        Contact Dell ProSupport and request expedited disk replacement
        A single disk has failed; spare reconstruction is in progress Moderate - RAID6 protection remains intact
         
        Follow the standard service request replacement process

Step 2 - Contact Dell ProSupport:

    1. Gather the following information before contacting support. This accelerates diagnosis and replacement:
      • INFORMATION NEEDED: HOW TO OBTAIN:
        System model and service tag # system show serialno
        Current disk states
        # disk show state
        Disk failure history
        # disk show failure-history
        Active alerts, including STORAGE-00009 output
        # alerts show current
        Drive model and firmware version # disk show hardware
        Number of pending replacement disks Your existing service request records
        Support Bundle (may be requested if additional investigation is required) Data Domain: How To Collect a Data Domain Support Bundle
    2. Contact Dell ProSupport or your contracted Support Provider and clearly communicate the situation, including:
      • The RAID protection state (critical, degraded, or reconstructing).
      • The number of failed disks and affected disk groups.
      • Whether replacement disks are pending delivery.

Step 3 - Take interim protective actions while awaiting replacement disks:

    1. Monitor disk health by running `disk show state` at least twice daily to detect any additional failures immediately.
    2. Reduce non-critical workload where possible. Pause non-essential backup schedules and replication jobs to lower I/O load on degraded disk groups.
    3. Do not power-cycle the system** unless Dell ProSupport explicitly directs you to do so.
    4. If an additional disk fails in an already-degraded disk group, contact Dell Support immediately - do not wait for the next business day.

Step 4 - Replace failed disks:

    1. Replace failed disks promptly as replacement hardware arrives. Each replaced disk becomes an available spare for RAID reconstruction.
    2. After replacement, verify that RAID reconstruction begins by running:
      • # disk show state
    3. Continue monitoring until reconstruction completes and the STORAGE-00009 alert clears.

Affected Products

Data Domain, Data Domain, PowerProtect Data Protection Hardware

Products

Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family
Article Properties
Article Number: 000203752
Article Type: Solution
Last Modified: 10 Jul 2026
Version:  8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.