PowerFlex 3.X:在 Windows 节点上安装 SDC 3.6-400.107 失败

Summary: 在 Windows 主机上安装 SDC 版本 3.6.0.4 失败。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

操作系统:Windows(任何)
SDC 版本:3.6.0.4

安装 SDC v3.6.0.4 失败并显示以下错误。
There is a problem with this Windows Installer package.无法运行完成此安装所需的程序。Contact your support personnel or package vendor.

安装 SDC Windows 
 

在setupapi.dev.log(位于 %SystemRoot%\inf 中),您会看到以下错误。
>>>  [SetupCopyOEMInf - C:\Program Files\EMC\scaleio\sdc\bin\driver_package\\scini.inf]
>>>  Section start 2022/08/15 00:15:12.038
      cmd: "C:\Program Files\EMC\scaleio\sdc\bin\drv_install.exe" install "scini" "C:\Program Files\EMC\scaleio\sdc\bin\driver_package\\scini.inf" "C:\Users\ADMINI~1\AppData\Local\Temp\EMC_install_log.txt"
     inf: Copy style: 0x00000002
<<<  Section end 2022/08/15 00:15:12.088
<<<  [Exit status: FAILURE(0x00000002)]
 
升级到 v3.6.0.4 时,setupapi.dev.log无法设置 MDM IP。
** setupapi.dev.log **
Called to update with inf C:\Program Files\EMC\scaleio\sdc\bin\driver_package\\scini.inf
Error (0x2):Error in SetupCopyOEMInf,The system cannot find the file specified.
Doing update with inf C:\Program Files\EMC\scaleio\sdc\bin\driver_package\\scini.inf
Successfully updated driver. Reboot needed 1
 

Cause

drv_cfg.exe是 v3.6.0.4 软件包的一部分,已损坏。

Resolution

升级或安装 SDC for Windows 版本 3.6.0.5 及更高版本。
要检查 SDC 兼容性,请参阅 PowerFlex作系统作系统支持矩阵

如果在更高的 SDC 版本中观察到类似错误,请确保安装了最新的 Windows 更新。