NetWorker: Tomcat logs cause /nsr/nwui/monitoring/app/logs directory to become excessively full
Summary: Tomcat logs cause /nsr/nwui/monitoring/app/logs directory to become excessively full due to it repeating the same ~283 lines again and again.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- NetWorker Web User Interface (NWUI) server is installed on a Linux operating system.
- In /nsr/nwui/monitoring/app/logs/monitoring-app.log
Error starting ApplicationContext. To display the conditions report re-run your application with 'debug' enabled. 2023-07-27 11:29:06.145 [SpringApplication] [main] ERROR org.springframework.boot.SpringApplication - Application run failed org.springframework.beans.factory.BeanCreationException:
Error creating bean with name 'entityManagerFactory' defined in class path resource [org/springframework/boot/autoconfigure/orm/jpa/HibernateJpaConfiguration.class]: Invocation of init method failed; nested exception is org.hibernate.service.spi.ServiceException: Unable to create requested service [org.hibernate.engine.jdbc.env.spi.JdbcEnvironment]
<snip>
Repeats
Cause
NWUI configuration issue.
Resolution
Rerun the nwui_configure script to reconfigure NWUI.
- Stop NWUI service: sudo systemctl stop nwui
- Run the NWUI configuration script: sudo /opt/nwui/scripts/nwui_configure.sh
- Start NWUI service: sudo systemctl start nwui
Affected Products
NetWorker Series, NetWorker Management ConsoleArticle Properties
Article Number: 000216793
Article Type: Solution
Last Modified: 26 May 2026
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.