PowerEdge: PM1653 and PM1655 SAS SSD Drive Models may Experience Unexpected Fault Condition

Summary: Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

If examining drive events, the Dell Samsung SSD drive models on Firmware versions DSG5, DWG5, or earlier firmware, either of the following SCSI sense key codes may be returned: 
0x3, 0x11, 0x0, or 0x4, 0x29, 0x4.
This issue may occur on any Dell platform or Dell solution that supports these drives.

Cause

Drive firmware

Resolution

The following cumulative fixes are contained in firmware revisions DSG8 and DWG8.

- SAS4 Signal Integrity improvements for 16G
- 2 Fixes for 04/29/04 FW assert conditions on Power On Reset and IT Nexus loss testing
- 2 Fixes for FW asserts that occurred during reset testing
- 2 Fixes for FW assert conditions during Write same testing with Aborts injected
- Resolved a timeout condition during link down error injection testing
- Resolved low likelihood cases where false Unrecovered Errors could occur on NAND reads
- Resolved an issue where Background Extended Drive Self-test could exceed the 30 minute spec limit

Dell Technologies recommends updating to the newest drive firmware at the earliest possible opportunity.
For these affected drive models, update the drive firmware to DSG8 or to DWG8 as per the below list.

Drive model  Dell Part Number   Drive capacity   Affected firmware   Firmware update 
PM1653 Series        
MZILG960HCHQAD3 H8DG4 960 GB DSG5 or earlier DSG8
MZILG1T9HCJRAD3 NRR34 1.92 TB DSG5 or earlier DSG8
MZILG3T8HCLSAD3 9N32F 3.84 TB DSG5 or earlier DSG8
PM1655 Series        
MZILG1T6HCJRAD3 5RJND 1.60 TB DWG5 or earlier DWG8
MZILG800HCHQAD3 3CHC8 800 GB DWG5 or earlier DWG8


For VxRail, see article Dell VxRail: Dell PM1653, PM1655 SAS SSD drive models may experience unexpected fault conditions

Affected Products

VxRail, XC Core Systems, XC Series Appliances, PowerProtect Data Manager Appliance, PowerFlex Appliance, PowerFlex custom node, MD Series, ME Series, APEX Cloud Platform for Microsoft Azure, PowerEdge R250, PowerEdge R260, PowerEdge R320 , PowerEdge R330, PowerEdge R360, PowerEdge R520, VxRail Appliance Family ...

Products

PowerProtect Data Protection Appliance, Modular Infrastructure, Rack Servers, Tower Servers, XR Servers, OEM Server Solutions, PowerProtect Data Manager, PowerEdge R540, PowerEdge R550, PowerEdge R6515, PowerEdge R6525, PowerEdge R660 , PowerEdge R660xs, PowerEdge R6615, PowerEdge R860, PowerEdge R910, PowerEdge R940, PowerEdge R960 ...
Article Properties
Article Number: 000222201
Article Type: Solution
Last Modified: 20 May 2026
Version:  7