PowerEdge: Seagate Summit SAS or SATA Drives Report Medium Errors or Sense Key 3/11 Read Errors

Summary: Seagate Summit SAS/SATA drives report medium errors or sense key 3/11 on PowerEdge and PowerVault systems due to a firmware issue causing weak writes to a drive sector.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Dell PowerEdge and PowerVault systems with Seagate Summit drives report sense key 03/11 and medium errors. Drives with excessive read errors may also report a predictive failure or SMART alert.

 

Cause

Dell Engineering has identified a firmware issue that can result in weak writes to a drive sector. Subsequent reads in this sector report a sense key 3/11 or a medium error as the initial write was not completed correctly.

 

Resolution

Update Seagate Summit SAS and SATA hard drive firmware at the earliest available opportunity to avoid impact to data.

  • The firmware versions in which this issue is resolved are listed below:
Drive P/N Firmware Version Firmware P/N Capacity Drive Type
FN7VR SWS8 W6DKH 12 TB SAS
R0G8W SYS8 MGW24 16 TB SAS
R5KP7 SYS8 MGW24 20 TB SAS
GPP63 SUS8 1V0FN 24 TB SAS
FYGY1 SYA5 NHVNM 12 TB SATA
VHFPR SYA5 NHVNM 16 TB SATA
P6GW1 SYA5 NHVNM 20 TB SATA
34MF5 SUA5 3J12C 24 TB SATA
NOTE: After updating drive firmware, confirm that data reliability features such as Patrol Read and Consistency Check within the Dell PowerEdge RAID Controller (PERC) are enabled. Reference specific PERC user guides from Dell Support Home.

These features are not available on system configurations where the operating system (OS) has direct access to drives through an HBA. Industry-standard OS utilities should be used instead to verify data integrity.

Patrol Read:
The Patrol read feature is designed as a preventative measure to ensure physical disk health and data integrity. Patrol read scans and resolves potential problems on configured physical disks.

The Dell OpenManage Storage Management application can be used to start patrol-read and change its behavior.

Some properties of the patrol-read feature are:

  • Runs on all disks on the controller that are configured as part of a virtual disk, including hot-spares
  • The Patrol read feature does not run on physical disks that are not part of non-RAID disks, virtual disks, or drives that are in Ready state.
  • The amount of controller resources dedicated to patrol read operations adjusts based on the number of outstanding disk I/O operations. For example, if the system is processing a large number of I/O operations, then patrol read uses fewer resources to allow the I/O to take a higher priority.
  • Patrol read does not run on disks that are involved in any of the following operations:
    • Rebuild
    • Replace member
    • Full or background initialization
    • Consistency Check
    • Online capacity expansion (OCE)
NOTE: By default, patrol read automatically runs every seven days on configured hard drives. (There is no requirement to install OpenManage for this feature to automatically run)

Consistency Check:
Consistency Check (CC) is a background operation that verifies and corrects the mirror or parity data for fault tolerant virtual disks. It is recommended that you periodically run a consistency check on virtual disks. You can manually start a CC using the HII Configuration Utility or the PERC CLI application.

NOTE: CC or BGI typically causes some loss in performance until the operation completes.

CC and BGI both correct parity errors, however, CC reports data inconsistencies through an event notification, while BGI does not. You can start CC manually, but not BGI.

Background Initialization:
Background Initialization (BGI) is an automated process that writes parity or mirror data on newly created virtual disks. BGI does not run on RAID 0 virtual disks. You can control the BGI rate in the HII application. Any change to the BGI rate does not take effect until the next BGI operation is started.

  • If you cancel BGI, it automatically restarts within five minutes.
  • Unlike full or fast initialization of virtual disks, background initialization does not clear data from the physical disks.
  • Consistency Check, and BGI typically cause some loss in performance until the operation completes.

 

Affected Products

AX-760, Dell EMC XC Core XC450, Dell EMC XC Core XC750, Dell XC Core XC660xs, Dell XC Core XC760, PowerEdge C6520, PowerEdge R250, PowerEdge R260, PowerEdge R350, PowerEdge R360, PowerEdge R450, PowerEdge R470, PowerEdge R550, PowerEdge R650xs , PowerEdge R6515, PowerEdge R6525, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R670, PowerEdge R6715, PowerEdge R6725, PowerEdge R740XD2, PowerEdge R750, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760xd2, PowerEdge R7615, PowerEdge R7625, PowerEdge R770, PowerEdge R7715, PowerEdge R7725, PowerEdge T150, PowerEdge T160, PowerEdge T360, PowerEdge T550, PowerEdge T560, PowerEdge T630, PowerEdge XE7420, PowerEdge XE7440, Dell EMC PowerVault ME4012, Dell EMC PowerVault ME4024, Dell EMC PowerVault ME4084, Dell EMC PowerVault ME412 Expansion, Dell EMC PowerVault ME424 Expansion, Dell EMC PowerVault ME484, PowerVault ME5012, PowerVault ME5024, PowerVault ME5084, PowerVault MD2412, PowerVault MD2460, Dell EMC XC Core XC7525 ...
Article Properties
Article Number: 000239838
Article Type: Solution
Last Modified: 21 May 2026
Version:  8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.