PowerFlex:退出 PMM 时遇到高卷延迟
Summary: 退出受保护维护模式 (PMM) 可能会导致卷延迟暂时增加。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- 故障集正在使用中,多个 SDS 同时退出 PMM。
显示 PowerFlex 卷延迟的 ESXi 日志:
2025-03-26T19:20:58.764Z Wa(180) vmkwarning: cpu33:2098795)WARNING: ScsiDeviceIO: 1772: Device eui.##### performance has deteriorated. I/O latency increased from average value of 350 microseconds to 28802 microseconds.
显示示例 comb 的 PMM 迁移的 SDS 跟踪日志 — 完成 comb 746b009a00b6 的内部迁移大约需要 27 毫秒。
2025/03/26 14:20:58.730516 MED:7f19cf3cedb0:contCmd_EndMigration:06164: CombId 746b009a00b6 - Start rc = SUCCESS
2025/03/26 14:20:58.730757 MED:7f19cf3cedb0:raidComb_EndExitPmmInter:02999: Comb 746b009a00b6: PMM becomes Rebuild (PMM remote 41a8b5e300000023), (Old rebuild remote 41a8b5df00000012).
2025/03/26 14:20:58.757184 MED:7f19cf3cedb0:contCmd_EndMigration:06197: CombId 746b009a00b6 - Done rc = SUCCESS
影响
退出 PMM 时 SDC 客户端观察到临时卷延迟
Cause
在退出 PMM 期间,梳子会停止,从而阻止 I/O作。延迟主要在 raidComb_EndExitPmmInter 函数的最后阶段引入,在此过程中系统会强化位图。
虽然此作通常很快,但在这种情况下,由于涉及大量梳子,延迟更为明显,这可能是由同时退出 PMM 的完整故障集引起的。这增加了在强化阶段遇到多个 Comb 的可能性,从而放大了 SDC 客户端观察到的延迟的影响。
Resolution
防止此问题的可能解决方案:
- 使用即时维护模式 (IMM)。
- 一次只能在单个 SDS 上退出 PMM。
受影响的版本
PowerFlex 3.x
PowerFlex 4.x
已修复问题的版本
PowerFlex 4.5.5