PowerFlex:退出 PMM 時發生高容量延遲

Summary: 退出受保護的維護模式 (PMM) 可能會暫時提高磁碟區延遲時間。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 

  • 故障組正在使用中,多個 SDS 同時退出 PMM。

 

ESXi 記錄顯示 PowerFlex 磁碟區的延遲:

2025-03-26T19:20:58.764Z Wa(180) vmkwarning: cpu33:2098795)WARNING: ScsiDeviceIO: 1772: Device eui.##### performance has deteriorated. I/O latency increased from average value of 350 microseconds to 28802 microseconds.
 

 

SDS 追蹤記錄顯示範例梳子的 PMM 遷移 - 完成梳子 746b009a00b6 的內部遷移大約需要 27 毫秒。

 
2025/03/26 14:20:58.730516 MED:7f19cf3cedb0:contCmd_EndMigration:06164: CombId 746b009a00b6 - Start rc = SUCCESS  
2025/03/26 14:20:58.730757 MED:7f19cf3cedb0:raidComb_EndExitPmmInter:02999: Comb 746b009a00b6: PMM becomes Rebuild (PMM remote 41a8b5e300000023),  (Old rebuild remote 41a8b5df00000012). 
2025/03/26 14:20:58.757184 MED:7f19cf3cedb0:contCmd_EndMigration:06197: CombId 746b009a00b6 - Done rc = SUCCESS
 

 

影響

SDC 用戶端在結束 PMM 時觀察到的暫時磁碟區延遲

Cause

在退出 PMM 期間,梳子會靜止,避免 I/O 作業。延遲主要在raidComb_EndExitPmmInter函數的最後階段引入,系統在該階段強化位圖。
雖然此操作通常很快,但在這種情況下,延遲更為明顯,因為涉及大量梳理,可能是由同時退出 PMM 的完整故障集造成的。這增加了在硬化階段遇到多個梳子的可能性,從而放大了 SDC 用戶端觀察到的對延遲的影響。

Resolution

防止此問題的可能解決方案:

  • 使用立即維護模式 (IMM)。
  • 一次僅退出單一 SDS 上的 PMM。

 

受影響的版本

PowerFlex 3.x

PowerFlex 4.x

已修正問題的版本

PowerFlex 4.5.5 

Affected Products