OpenManage Enterprise: Inventory Not Reflecting Updated Firmware After External Updates
Summary: When firmware updates are applied to Dell PowerEdge servers outside of the OpenManage Enterprise (OME) workflow, the OME inventory may not reflect the updated versions. Running a manual inventory task or re-onboarding the device in OME will force a re-detection and resolve the discrepancy. ...
Instructions
Description
When firmware updates (such as BIOS, iDRAC, or other components) are applied to Dell PowerEdge servers outside of the OpenManage Enterprise (OME) workflow — for example, through iDRAC directly, Lifecycle Controller, Dell Repository Manager (DRM), or manual updates — the OME console may continue to display the previous firmware versions. This occurs because OME was not the tool used to perform the update and therefore did not automatically trigger an inventory refresh upon completion.
This article describes how to resolve the stale inventory data by running a manual inventory task or re-onboarding the device.
Symptoms
- OME inventory displays outdated firmware versions for one or more components (BIOS, iDRAC, NIC, RAID, etc.) even though updates have been successfully applied on the host.
- Firmware compliance reports in OME show devices as non-compliant despite the firmware already being at the expected version on the server itself.
- Discrepancy between firmware versions shown in OME versus what is reported in iDRAC or Lifecycle Controller.
Root Cause
OME automatically triggers an inventory refresh only when updates are performed through its own update workflow. When firmware is applied through any method outside of OME, the console has no awareness that a change occurred and continues to report the last known inventory state.
Resolution
Option 1: Run a Manual Inventory Task
- Log in to OpenManage Enterprise.
- Navigate to Monitor → Inventory.
- Click Create Inventory Task (or Run Inventory).
- Select the target device(s) that were updated externally.
- Choose to run the task immediately or schedule it.
- Click Finish to execute the inventory task.
- Once the task completes, verify that the firmware versions displayed in OME now reflect the updated versions.
Option 2: Re-onboard the Device
If running a manual inventory task does not resolve the discrepancy, re-onboarding the device will force OME to fully re-inventory the server.
- Log in to OpenManage Enterprise.
- Navigate to Devices → All Devices.
- Locate the affected device and select it.
- Click on Discovery.
- Onboard the device, the wizard will prompt for iDRAC credentials.
- Once onboarding completes, verify that the inventory reflects the correct firmware versions.
Additional Notes
- This behavior is expected and by design. OME does not continuously poll devices for firmware changes outside of scheduled or triggered inventory tasks.
- The same behavior applies to OMEVV (OpenManage Enterprise Integration for VMware vCenter). If firmware is updated on ESXi hosts outside of the OMEVV workflow, a manual inventory refresh or re-onboarding in OMEVV is required.
- No server reboot or additional downtime is required to run an inventory task in OME