Article Number: 541853

printer Print mail Email

RecovePoint: Dr data corruption with VMAX3/AF

Summary: DR Data corruption with VMAX3/AF

Primary Product: RecoverPoint

Product: RecoverPoint more...

Last Published: 21 Apr 2020

Article Type: Break Fix

Published Status: Online

Version: 4

RecovePoint: Dr data corruption with VMAX3/AF

Article Content

Issue


Data inconsistency on DR snapshot may occur post undo writes operation during image access
No error are logged on the VMAX side

From CLI

  Time:                 Sat Aug 24 20:10:41 2019
  Topic:                GROUP
  Scope:                NORMAL
  Level:                ERROR
  Event ID:             4108
  Cluster:              Cork
  Global links:         None
  RPA:                  RPA 2
  Groups:               [Test, Prod]
  Links:                [Test, Prod-remote]
  Volumes:              [Test, remote, RSet0]
  Summary:              Replication integrity issue detected
  Details:              The data in the following blocks differ  ... ABBRIDGED

 

Cause

Improper handling of SDDF in the VMAX microcode.

Resolution

Workaround:

Force a full sweep on the affected Cg to resolve the corruption, the issue will re-occur until the permanent fix is applied

Resolution:


This issue is addressed in the Vmax microcode 5978.221.221 fix 104350  version and above.
You should always upgrade Vmax microcode to the latest cumulative code

To determine whether an upgrade is appropriate for your environment, contact the Dell EMC Customer Support Center or your service representative and reference this solution ID.

Notes

Issue


Data inconsistency on DR snapshot may occur post undo writes operation during image access
No error are logged on the VMAX side

From CLI

  Time:                 Sat Aug 24 20:10:41 2019
  Topic:                GROUP
  Scope:                NORMAL
  Level:                ERROR
  Event ID:             4108
  Cluster:              Cork
  Global links:         None
  RPA:                  RPA 2
  Groups:               [Test, Prod]
  Links:                [Test, Prod-remote]
  Volumes:              [Test, remote, RSet0]
  Summary:              Replication integrity issue detected
  Details:              The data in the following blocks differ  ... ABBRIDGED

 

Cause

Improper handling of SDDF in the VMAX microcode.

Resolution

Workaround:

Force a full sweep on the affected Cg to resolve the corruption, the issue will re-occur until the permanent fix is applied

Resolution:


This issue is addressed in the Vmax microcode 5978.221.221 fix 104350  version and above.
You should always upgrade Vmax microcode to the latest cumulative code

To determine whether an upgrade is appropriate for your environment, contact the Dell EMC Customer Support Center or your service representative and reference this solution ID.