ECS:OBS:xDoctor:xDoctor 在主要節點控制檢查訊息顯示後無法執行
Summary: xDoctor 無法執行,並在一秒後結束。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
xDoctor 無法執行,並在一秒後結束:
admin@ecs1node1:~> sudo xdoctor --hr
2025-11-19 10:44:03,765: 5.1-106.1 - INFO : Adding Work - Job:1763549043 (P9) [* * * * * *] (--scope=SYSTEM --suite=default): From CLI
2025-11-19 10:44:03,766: 5.1-106.1 - INFO : Executing Job:1763549043 - session_1763549043.766
2025-11-19 10:44:03,798: 1763549043.766 - INFO : Initializing xDoctor v5.1-106.1 ...
2025-11-19 10:44:03,809: 1763549043.766 - INFO : xDoctor Composition - Full Diagnostic Suite for ECS
2025-11-19 10:44:03,814: 1763549043.766 - INFO : Starting xDoctor session_1763549043.766 ... (SYSTEM)
2025-11-19 10:44:03,814: 1763549043.766 - INFO : Primary Node Control Check ...
Traceback (most recent call last):
File "/opt/emc/xdoctor/lib/xdoctor/lib/cli.py", line 526, in __execute
engine = Engine(session_id)
^^^^^^^^^^^^^^^^^^
File "/opt/emc/xdoctor/lib/xdoctor/core/engine.py", line 281, in __init__
if self.system.is_primary() == False:
^^^^^^^^^^^^^^^^^^^^^^^^
File "/opt/emc/xdoctor/lib/xdoctor/lib/system.py", line 799, in is_primary
return self.config['hosts'][self.host]['state'].startswith('M')
~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^
KeyError: '169.254.2.1'
2025-11-19 10:44:04,106: 5.1-106.1 - ERROR : Failures in Job:1763549043 Exit Code:1 (Internal Failure)
admin@ecs1node1:~>
Cause
xDoctor 必須從控制節點啟動。通常這是機架中的第一個節點。
如果發生此錯誤,xDoctor 將無法判斷控制節點並停止執行。
此錯誤可能會在節點擴充後發生。
Resolution
請開啟服務要求以連絡 Dell 技術支援 部門尋求協助,並參閱此知識文章。
Affected Products
ECSProducts
ECS Appliance, ECS Appliance Software with Encryption, ECS Appliance Software without EncryptionArticle Properties
Article Number: 000394248
Article Type: Solution
Last Modified: 09 Dec 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.