ECS:OBS:xDoctor:显示主节点控制检查消息后xDoctor运行失败
Summary: xDoctor 无法运行并在一秒钟后退出。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
xDoctor 无法运行并在一秒钟后退出:
admin@ecs1node1:~> sudo xdoctor --hr
2025-11-19 10:44:03,765: 5.1-106.1 - INFO : Adding Work - Job:1763549043 (P9) [* * * * * *] (--scope=SYSTEM --suite=default): From CLI
2025-11-19 10:44:03,766: 5.1-106.1 - INFO : Executing Job:1763549043 - session_1763549043.766
2025-11-19 10:44:03,798: 1763549043.766 - INFO : Initializing xDoctor v5.1-106.1 ...
2025-11-19 10:44:03,809: 1763549043.766 - INFO : xDoctor Composition - Full Diagnostic Suite for ECS
2025-11-19 10:44:03,814: 1763549043.766 - INFO : Starting xDoctor session_1763549043.766 ... (SYSTEM)
2025-11-19 10:44:03,814: 1763549043.766 - INFO : Primary Node Control Check ...
Traceback (most recent call last):
File "/opt/emc/xdoctor/lib/xdoctor/lib/cli.py", line 526, in __execute
engine = Engine(session_id)
^^^^^^^^^^^^^^^^^^
File "/opt/emc/xdoctor/lib/xdoctor/core/engine.py", line 281, in __init__
if self.system.is_primary() == False:
^^^^^^^^^^^^^^^^^^^^^^^^
File "/opt/emc/xdoctor/lib/xdoctor/lib/system.py", line 799, in is_primary
return self.config['hosts'][self.host]['state'].startswith('M')
~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^
KeyError: '169.254.2.1'
2025-11-19 10:44:04,106: 5.1-106.1 - ERROR : Failures in Job:1763549043 Exit Code:1 (Internal Failure)
admin@ecs1node1:~>
Cause
xDoctor 必须从控制节点启动。通常这是机架中的第一个节点。
如果发生此错误,xDoctor 无法确定控制节点并停止运行。
节点扩展后可能会发生此错误。
Resolution
通过创建服务请求联系戴尔技术支持 以获得帮助,并参阅此知识库文章。
Affected Products
ECSProducts
ECS Appliance, ECS Appliance Software with Encryption, ECS Appliance Software without EncryptionArticle Properties
Article Number: 000394248
Article Type: Solution
Last Modified: 09 Dec 2025
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.