Avamar:Data Domain 后端容量报告无法运行:“功能未启用”

Summary: 不会为 Data Domain 运行 Avamar 后端容量报告,报告“功能未启用”。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Data Domain (DD) 的后端容量报告不会运行,并报告“功能未启用”(如下所示):

kA2j0000000RKTMCA4_3_0

 

Cause

Data Domain 后端容量报告需要 compression physical-capacity-measurement 在 Data Domain作系统 (DDOS) 5.7.x 及更高版本上可用的 Data Domain 上的功能待启用。

Resolution

1.确保 Data Domain 正在运行 DDOS 5.7.x 或更高版本。

2.验证是否已在 Data Domain 上启用物理容量测量功能:

compression physical-capacity-measurement status
 

如果已启用:

physical-capacity-measurement is enabled.
Initialization was not requested.
 

如果已禁用:

physical-capacity-measurement is disabled.
 

3.如果禁用,请使用以下命令启用:

compression physical-capacity-measurement enable
physical-capacity-measurement enabled.