PowerEdge Server : AC Recovery Last Power State Behavior

Resumen: If the power state is set to last, and a forced shutdown event occurs, the system will power back on if the AC is lost and then restored.

Es posible que este artículo se traduzca automáticamente. Si tiene comentarios sobre su calidad, háganoslo saber mediante el formulario en la parte inferior de esta página.

Contenido del artículo


Síntomas

SLN288806_en_US__1icon Note: This article is part of the Server Tutorials: "Power Supply" available here .
This article provides information on PowerEdge AC recovery last power state behavior.

Question 


Before 12th server Generation, if a forced ungraceful power down is asserted the last power state setting is not maintained.
For example if a 11G Sever is running, and the power is cut, when the power will be back, the server won't start automatically.

On PowerEdge™ 12th Generation (12G) and later systems if the power state is set to last, and a forced shutdown event occurs, the system will power back on if the AC is lost and then restored.
This setting can be configured in the BIOS on the server. 
 


BIOS Configuration


This option can be configure in the BIOS (F2), then in the System Security Screen


AC Power Recovery
Allows you to set how the system reacts after AC power is restored to the system. By default, the AC Power Recovery option is set to Last.


AC Power Recovery Delay
Allows you to set how the system supports staggering of power up after AC power is restored to the system. By default, the AC Power Recovery Delay option is set to Immediate.


User Defined Delay (60s to 240s)
Allows you to set the User Defined Delay when the User Defined option for AC Power Recovery Delay is selected.