NetWorker: ddboost device mount fails with Error 5044 Read-only file system
Resumen: NetWorker fails to mount ddboost device with error 5044 read-only file system.
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
The NetWorker server fails to mount a ddboost device after Orchestrated Replication on the Destination NetWorker Server. The NetWorker Management Console (NMC) shows the following error:
ddp_utime() failed path_name=/nwservername/devicename/volhdr Err 5044 Read-only file system
The Data Domain mtree list shows:
Causa
If the MTree is RO/RD, it cannot accept writes because it is a replication target. The NetWorker Storage Node expects a ddboost device to be writable when mounting.
- RW = Read Write → The MTree is read writable.
- RO = Read Only → The MTree cannot accept any write operations.
- RD = Replication Destination → The MTree is the target of replication and is locked for writes
Resolución
The NetWorker configuration should reflect that this Data Domain ddboost device in read-only. This option skips write-related operations (like labeling or updating media) and allows the mount to succeed.
- In the NMC, right-click replicated device and device properties -> enable the Read-only checkbox.
- Mount the replicated device.

Productos afectados