VNX: How to attach same CIFS interface as NFS to the same VDM
Resumen: It is only possible to attach the same CIFS Interface as NFS to the same VDM through CLI Commands.
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Instrucciones
Connect to the Control Station SSH.
In order to view the interfaces attached as CIFS or NFS , apply the below command:
$nas_server -i -v <VDM_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs
The above example shows Interface Name "nl0123nas0002_390" is attached as CIFS only, and Interface Name "Prodspace" is attached as CIFS and NFS.
To attach the same CIFS interface as NFS apply the below command:
$nas_server - vdm <VDM_Name> -attach <Interface_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs
In order to view the interfaces attached as CIFS or NFS , apply the below command:
$nas_server -i -v <VDM_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs
The above example shows Interface Name "nl0123nas0002_390" is attached as CIFS only, and Interface Name "Prodspace" is attached as CIFS and NFS.
To attach the same CIFS interface as NFS apply the below command:
$nas_server - vdm <VDM_Name> -attach <Interface_Name>
Example:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs
Productos afectados
VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700Productos
VNX5800, VNX7500, VNX7600, VNX8000Propiedades del artículo
Número del artículo: 000192930
Tipo de artículo: How To
Última modificación: 07 jul 2026
Versión: 5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.