Data Domain: NVRAM Remote Battery Failure Alert | NVRAM-00202
Resumen: This article explains the cause and resolution of the NVRAMRemoteBatteryFailure alert (Event ID: EVT-NVRAM-00202) on Data Domain systems; This alert indicates a critical hardware fault with the NVRAM remote battery, which must be resolved before the file system can be accessed. ...
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
- Event ID:
EVT-NVRAM-00202- Alert:
NVRAMRemoteBatteryFailure - Message: "A hardware fault was detected with an NVRAM remote battery and it may need to be replaced."
- Alert:
- Filesystem is down with NVRAM alerts posted.
Example:
-
Alert ID: EVT-NVRAM-00202 Severity: Critical Class: hardwareFailure Object: Slot=%s Info: Cause=%s (see list below) Message: A hardware fault was detected with an NVRAM remote battery and it may need to be replaced Description: The remote battery for an NVRAM card is not in an usable state. The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replaced.
APPLIES TO
- All Data Domain systems
Causa
This alert is triggered when the system detects that the NVRAM remote battery is unreliable or unusable. The specific cause is detailed in the alert message (Info: Cause=). Possible causes include:
- Unable to retrieve NVRAM battery status
- Battery not detected
- Battery not charging
- Voltage levels critically high:
- Battery 1 voltage: High Critical
- Battery 2 voltage: High Critical
- Battery 3 voltage: High Critical
- Multiple battery failures detected
Resolución
To resolve the issue:
- Check iDRAC (System Event Log) - SDPM/VOSS systems only
- Confirm the affected battery
- Check for related alerts and symptom codes and address them accordingly
-
Inspect physical connections:
- Ensure all cables between the NVRAM card, and the remote battery are securely connected.
- Verify that the power cable from the system to the remote battery unit is properly seated.
- If the system was previously powered off for an extended period of time, wait for the batteries to charge >=80%
-
Replace faulty components:
- If any cables are damaged or defective, replace them.
- If all connections are intact and the alert persists, replace the remote backup battery unit.
Productos afectados
PowerProtect Data Manager Appliance, Data Domain, PowerProtect Data ManagerPropiedades del artículo
Número del artículo: 000042368
Tipo de artículo: Solution
Última modificación: 25 ago 2026
Versión: 7
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.