VxRail: Event Code: VXR508STOR371

Resumen: Event Code VXR508STOR371 indicates: Unable to use the physical drive arg1 because the drive selected is not unmap-capable for virtual drive configuration.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

iDRAC event STOR371 occurs and YELLOW alarm 'VXR508STOR371' presents in vCenter portal.

Causa

The physical drive identified in the message cannot be used because the drive selected is not unmap-capable for virtual drive configuration.

Resolución

Replace the physical drive with an unmap-capable drive, and then retry the operation.

Productos afectados

VxRail, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N, VxRail E665, VxRail E665F, VxRail E665N , VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760 ...
Propiedades del artículo
Número del artículo: 000189229
Tipo de artículo: Solution
Última modificación: 01 may 2026
Versión:  6
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.