AppSync: Application Mapping failed while finding VPLEX virtual volumes

Resumen: AppSync isunable get the virtual volumes information with wwn: from VPLEX due to VPLEX management console issues.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

AppSync unable get the virtual volume information with wwn:<wwn_id> from VPLEX cluster due to VPLEX management console issues.
AppSync command failed: https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
 
The primary error found in the Server Log is:
 

Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n"
 

Details surrounding this error are found in the Server Log as seen here: 
 

<date>  10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date>  10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date>  10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date>  10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)



Causa

This issue is related to the VPLEX management console which is rejecting valid commands passed from AppSync through REST API. This is a known issue in VPLEX.

The reason for the NaN problem is currently believed to be CST JNI native code not being thread-safe and corrupting the FPU registers and interfering with other java threads that need to use the FPU (such as for double numbers).

Resolución

Permanent Resolution:
This issue is fixed in VPLEX GeoSynchrony code version 6.0 Service Pack 1 Patch 4 and later.

Workaround:

  1. Restart VPLEX management console.
  2. Re-run the AppSync service plan.

For more details on how to restart the VPLEX Management Console service refer to KB article 000167777: ViPR Controller : Creation of a VPLEX distributed lun fails with Status 524: Infinite or NaN 


Información adicional


 
 

Productos afectados

AppSync

Productos

AppSync, VPLEX Series
Propiedades del artículo
Número del artículo: 000057099
Tipo de artículo: Solution
Última modificación: 17 abr 2026
Versión:  5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.