Data Domain: hyperthreading mismatch | ENVIRONMENT-00049

Resumen: This article provides instructions to resolve CPU misconfiguration alerts on Dell EMC PowerProtect DD9900, DD9910, and DD9410 appliances. These alerts occur when hyperthreading settings do not match platform requirements. ...

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

The system reports the following alert during hardware verification:

EVT-ENVIRONMENT-00049: The system detected an invalid hardware configuration.

Running the misconfiguration check shows CPU hyperthreading mismatches, for example:

# enclosure show misconfiguration

CPUs:
Socket   Model       Cores   Logical Cores   Hyperthreading   Status
------   ---------   -----   -------------   --------------   ---------------
0        Gold 6140   18      36              on               hyperthreading mismatch
1        Gold 6140   18      36              on               hyperthreading mismatch
2        Gold 6140   18      36              on               hyperthreading mismatch
3        Gold 6140   18      36              on               hyperthreading mismatch
  • All other components show no misconfiguration.
  • This issue arises after motherboard replacement or after incorrect settings have been applied in BIOS.

Applies To:

  • PowerEdge-based Data domain Systems
    • This issue has been encountered on DD9910|DD9410|DD9900
      • It may also be encountered on other models if Hyper-Threading settings are not what they should be.
  • All DDOS software versions

Causa

During motherboard or memory replacement, the BIOS hyperthreading setting may not match the required configuration for the appliance model. The Device Inventory Verification (DIV) process detects the mismatch and generates the alert.

Resolución

Connect to the appliance’s iDRAC to correct the BIOS hyperthreading configuration and reboot the system.

1. Connect to the affected DD systems iDRAC interface.

  • Connect directly by pointing a browser at the configured iDRAC IP address.
    • OR | Alternatively (For example, Field Service):
      • Connect a laptop to the system’s RJ45 iDRAC port using a straight‑through Ethernet cable.
      • Configure the laptop with an IP address on the same subnet as the customer’s iDRAC network.
      • Access the iDRAC web interface.

2. Update Hyperthreading Settings.

  1. Navigate to:
    Configuration → BIOS Settings → Processor Settings
  2. Locate Logical Processor (this controls hyperthreading).
  3. Set the value based on the appliance model:
Appliance Model Required Setting
DD9900 Disabled
DD9910 Disabled
DD9410 Enabled
  1. Select Apply.
  2. Select Apply and Reboot.

3. Validate After Reboot

After the system restarts:

  1. In iDRAC:
    Verify the setting under:
    Configuration → BIOS Settings → Processor Settings → Logical Processor

  2. In the DDR CLI:
    Run the misconfiguration check:

    # enclosure show misconfiguration
    

Ensure that no CPU misconfiguration entries remain.

Productos afectados

Data Domain
Propiedades del artículo
Número del artículo: 000021469
Tipo de artículo: Solution
Última modificación: 23 ene 2026
Versión:  4
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.