PowerStore Alerts RxDefinition Aging BBU Detected

Resumen: This article describes the PowerStore alert for RxDefinition of aging BBU detected.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

An alert was raised for "Battery is aging."

 

Causa

The issue is detected within the periodic health check mechanism. See KB 000193518 PowerStore: Landing for Page RxDefinitions Issues for more information of the health check mechanism and a complete list of RxDefinitions.

Resolución

Alert ID POWERDOCTOR_ISSUE_MAJOR
Alert Text Battery is aging. It may not be able to protect the system KB# 000222221
Error Code 0x03700103
Description A backup battery unit (BBU) of the appliance is approaching its end of life. Battery failure can be the result of a BBU that has reached end of life. Failure of battery protection can lead to system failure. It may impact appliance operations and degrade high availability.
Resolution

Cause
The internal counters of the BBU have crossed the threshold that indicates the BBU is approaching its end of life. See the Additional Info section for more details.

Solution
The BBU must be replaced.
Contact Technical Support so they can review the underlying cause of the error to determine the best course of action.

 

Información adicional

Considerations:

  1. This check is designed to verify charging cycles for the BBU part numbers: '078-000-177-02', '078-000-211-01', '088-000-177-02', '088-000-211-01'
  2. If the alert was present before the failing BBU is replaced, the alert may remain active for an additional 48 hours after the BBU replacement.
  3. An alert is activated if there are eight or more charging cycles within the preceding 48 hours, irrespective of BBU age.
  4. During a power outage, the Battery Backup Unit (BBU) starts to discharge. When power is restored, the node recharges the BBU to its full capacity, which is recorded as one charging cycle. An alert may be issued if there are multiple power outages within a 48-hour window. If this occurs, it is advisable to wait for a continuous 48-hour period without any power interruptions to determine if the alert resolves itself.

See KB 000193518 PowerStore: Landing for Page RxDefinitions Issues for a complete list of RxDefinitions.

 

Productos afectados

PowerStore
Propiedades del artículo
Número del artículo: 000222221
Tipo de artículo: Solution
Última modificación: 14 jun 2025
Versión:  9
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.