PowerStore/PowerFlex/PowerMax: SNS export mount failure when using NFSv4
Resumen: Upon creating a file system (FS) with an identical name to the SNS name, SNS export cannot be mounted using NFSv4.
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
Upon creating a file system (FS) with an identical name to the SNS name, SNS export cannot be mounted using NFSv4.
Customer Impact:
SNS export using NFSv4 will fail to mount. As a result, access to the SNS links will fail and be redirected to link targets.
This issue affects: PowerFlex, PowerMax, and PowerStore
Customer Impact:
SNS export using NFSv4 will fail to mount. As a result, access to the SNS links will fail and be redirected to link targets.
This issue affects: PowerFlex, PowerMax, and PowerStore
Causa
This issue is due to SDNAS using a single namespace.
Resolución
Workaround:
Re-create the namespace with a different name.
The FS name should be different from the SNS root hosting file system name.
Important: Use the NFSv4 version mount option explicitly while mounting the namespace to avoid auto-failback to NFSv3.
Re-create the namespace with a different name.
The FS name should be different from the SNS root hosting file system name.
Important: Use the NFSv4 version mount option explicitly while mounting the namespace to avoid auto-failback to NFSv3.
Productos afectados
PowerFlex Appliance, PowerMax, PowerStorePropiedades del artículo
Número del artículo: 000216923
Tipo de artículo: Solution
Última modificación: 04 jul 2025
Versión: 7
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.