PowerStore/PowerFlex/PowerMax: SNS export mount failure when using NFSv4

Resumen: Upon creating a file system (FS) with an identical name to the SNS name, SNS export cannot be mounted using NFSv4.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

Upon creating a file system (FS) with an identical name to the SNS name, SNS export cannot be mounted using NFSv4. 

Customer Impact:
SNS export using NFSv4 will fail to mount. As a result, access to the SNS links will fail and be redirected to link targets. 


This issue affects: PowerFlex, PowerMax, and PowerStore

Causa

This issue is due to SDNAS using a single namespace.

Resolución

Workaround:
Re-create the namespace with a different name. 
The FS name should be different from the SNS root hosting file system name.

Important: Use the NFSv4 version mount option explicitly while mounting the namespace to avoid auto-failback to NFSv3.

Productos afectados

PowerFlex Appliance, PowerMax, PowerStore