Síntomas
In message ESNP1AII the number of tracks that are waiting to be defined was incorrectly being reported as 0.
Example (Dell EMC CS lab): ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:0 Inline: UTILITY A7 -- Show system devices Attrib/WP/Invalid utility_a7_c NOT WRT RDF READY DIS. TYPE GROUP DEVICE WRT | INVALID TRACKS COUNTS (PHCO) DV# M1234 1234 1234 I II ATTRIBUTES PEND | M1 M2 M3 M4 ---------------------------------------------------------|----------------------------------------------- 1AED .-.- .-.- T-F- BB ufsT...LTGT.......... 0 | 0 167772165 145815287 167772165 Expected behaviour: ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:167728193 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:150345220 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:108735872 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:95637968 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:76163641 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:70943775 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:65584717 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:42642180 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:17399737 ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:00001AED S/N:0001976018xx REMAINING TRACKS:3130933
Causa
This is due to a software issue.
Resolución
Processing was modified to correctly handle the timing issue to ensure the CQNAME order of commands is honored.
Permanent Fix:
Permanent Fix:
- For Mainframe Enablers 8.5, PTF SN85074 has been developed to correct the issue. It is available to download from Dell Online Support
Información adicional
Error Message:
ESNP1AII
WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:symdv#
S/N:symmserial REMAINING TRACKS:count
Cause
Before unlinking, the target device is queried to ensure it is defined. If it is not defined yet, this message is issued.
Action
None.
PTF Cover Note:
ESNP1AII
WAITING FOR TARGET TO BE FULLY DEFINED, DEVICE#:symdv#
S/N:symmserial REMAINING TRACKS:count
Cause
Before unlinking, the target device is queried to ensure it is defined. If it is not defined yet, this message is issued.
Action
None.
PTF Cover Note:
++PTF(SN85074) REWORK(2022053) . ++VER(Z038) FMID(SSNP850) PRE( SN85060 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * USERS AFFECTED: Snap operations on large R1 devices * PROBLEM DESCRIPTION: Incorrect track count value * DESCRIPTION DETAIL: * * In message ESNP1AII the number of tracks that are waiting to * be defined was incorrectly being reported as 0. * * ESNP1AII WAITING FOR TARGET TO BE FULLY DEFINED, * DEVICE#:0000XXXX S/N:XXXXXXXXXXXX REMAINING TRACKS:0 * * * PROBLEM RESOLUTION: * * The message format has been changed to display the correct * track count. * * MODULES: ESNAXBAR * * ------------------------------------------------------------ * SN85074 22 Feb 2022 08:03:48 * ------------------------------------------------------------
Productos afectados
Mainframe EnablersPropiedades del artículo
Número del artículo: 000197040
Tipo de artículo: Solution
Última modificación: 19 jun 2023
Versión: 5
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.