PowerStore: System Check detects unnecessary de-stages

Resumen: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.

Este artículo se aplica a Este artículo no se aplica a Este artículo no está vinculado a ningún producto específico. No se identifican todas las versiones del producto en este artículo.

Síntomas

If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"

Screenshot of the PowerStore Manager:image.png

When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check
Name                               Location  Status     Description
Datapath Dedup Destage Leak        node_a    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
Datapath Dedup Destage Leak        node_b    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
 
 
SUMMARY Status: Failed
   Passed:      0
   Failed:      2
   Total:       2
 

Causa

The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.

The issue is resolved in 3.6 and later.

Resolución

If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.

Información adicional

Productos afectados

PowerStore
Propiedades del artículo
Número del artículo: 000220203
Tipo de artículo: Solution
Última modificación: 14 jun 2025
Versión:  3
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.