VNX: HC_DM_14505148557 de erro e HC_DM_14505148498 de erro
Resumen: Falha na assinatura do SLIC e falha de ID exclusivo (corrigível pelo usuário)
Síntomas
O CE substituiu os DIMMs no Data Mover e o comando "setup_slot -init" apresentou falha com os erros de nas_checkup acima.
Blades : Check unique id Error HC_DM_14505148498: * The uniqueid reported by the Blade server_3 does not match the /nas/server/slot_3/start file. Action : Escalate this issue through your support organization if needed. Provide this output in the escalation.
Blades : Check slic signature Error HC_DM_14505148557: No SLIC signature in device file. grep slicsignature /nas/server/slot_3/device command failed with exit code 1. Action : Investigate by running the command manually. Escalate this issue through your support organization if needed and refer to EMC Knowledgebase number emc195492. Provide this output and the output from any commands that you ran for this procedure in the escalation.
Causa
slicsignature valida ID em /nas/server/slot_x/device
uniqueid validate ID em /nas/server/slot_x/start
[nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613
[nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0
Resolución
Outros KBAs exigem que você execute o comando setup_slot -init para eliminar falhas de assinatura do Slic. Descobri que o processo a seguir resolveu meu problema, mas você pode acabar precisando passar pelo processo setup_slot -init.
-
Examine a entrada do arquivo /nas/server/slot_x/start e a linha "uniqueid validate=".
-
Execute o seguinte comando para determinar qual deve ser a entrada uniqueid:
[nasadmin@ xxxxx ~]$ /nas/sbin/t2tty -C 3 "uniqueid" 1492624816: KERNEL: 6: WWN Seed (at address ffd80210): 46e05cb0 1492624816: SYSTEM: 6: uniqueid: "50060168:46e05cb0" 1492624816: ADMIN: 6: Command succeeded: uniqueid
-
Edite o arquivo /nas/server/slot_x/start usando o VI Editor e adicione o valor correto à linha "uniqueid validate=". Talvez seja necessário adicionar um texto à esquerda "uniqueid validate=" também.
[nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0 < --- Edit the last line in file.
-
Examine a entrada do arquivo /nas/server/slot_x/device e a linha "slicsignature validate". Se essa linha ou detalhes estiverem ausentes, vá para a próxima etapa.
-
Examine a saída do comando "/nasmcd/getreason -e" para determinar os códigos Slic do Data Mover.
[nasadmin@xxxxx~]$ /nasmcd/getreason -e 10 - slot_0 primary control station 5 - slot_2 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613) 5 - slot_3 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613)
-
Edite o arquivo /nas/server/slot_x/device usando o VI Editor e adicione o valor correto à linha "slicsignature validate=". Talvez seja necessário adicionar o texto principal "slicsignature validate=" também.
[nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613 < --- Edit the last line in file.
-
Execute novamente o "nas_checkup" para verificar se os erros foram corrigidos. Você pode executar "nas_checkup -rerun" para verificar apenas as falhas ou erros anteriores.
Encaminhe esse problema por meio de seu provedor de serviços, se necessário, e forneça o resultado nas_checkup no encaminhamento.