VNX: Error HC_DM_14505148557 en Error HC_DM_14505148498
Resumen: Slic-handtekeningfout en unieke id-fout (op te lossen door gebruiker)
Síntomas
CE heeft de DIMM's op de datamover vervangen en de opdracht "setup_slot -init" is mislukt met de bovenstaande nas_checkup fouten.
Blades : Check unique id Error HC_DM_14505148498: * The uniqueid reported by the Blade server_3 does not match the /nas/server/slot_3/start file. Action : Escalate this issue through your support organization if needed. Provide this output in the escalation.
Blades : Check slic signature Error HC_DM_14505148557: No SLIC signature in device file. grep slicsignature /nas/server/slot_3/device command failed with exit code 1. Action : Investigate by running the command manually. Escalate this issue through your support organization if needed and refer to EMC Knowledgebase number emc195492. Provide this output and the output from any commands that you ran for this procedure in the escalation.
Causa
slicsignature valideer ID ontbreekt in /nas/server/slot_x/device
uniqueid valideren dat ID ontbreekt in /nas/server/slot_x/start
[nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613
[nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0
Resolución
Bij andere KBA's moet u de opdracht setup_slot -init uitvoeren om fouten in de Slic-handtekening te wissen. Ik heb gemerkt dat het volgende proces mijn probleem heeft opgelost, maar het kan zijn dat u uiteindelijk het setup_slot-init-proces moet doorlopen.
-
Controleer de bestandsinvoer /nas/server/slot_x/start en controleer de regel "uniqueid validate=".
-
Voer de volgende opdracht uit om te bepalen wat de unieke id-vermelding moet zijn:
[nasadmin@ xxxxx ~]$ /nas/sbin/t2tty -C 3 "uniqueid" 1492624816: KERNEL: 6: WWN Seed (at address ffd80210): 46e05cb0 1492624816: SYSTEM: 6: uniqueid: "50060168:46e05cb0" 1492624816: ADMIN: 6: Command succeeded: uniqueid
-
Bewerk het bestand /nas/server/slot_x/start met VI Editor en voeg de juiste waarde toe aan de regel "uniqueid validate=". Mogelijk moet u ook de leidende tekst "uniqueid validate=" toevoegen.
[nasadmin@ xxxxx ~]$ cat /nas/server/slot_3/start -serial swapserial #verify_start flashupg post=upgrade bios=upgrade fwbd=upgrade logsys add output disk=root_log_3 bufsz=256 logsys add output event bufsz=2048 ap boot setid celerraid=APXXXXXXXXXXXXXXXX setinitiator cs_hostname=Celerra_ xxxxx cs_external_ip=10.241.183.190 uniqueid validate=50060168:46e05cb0 < --- Edit the last line in file.
-
Controleer de bestandsinvoer /nas/server/slot_x/device en controleer de regel "slicsignature validate". Als deze regel of details ontbreken, gaat u verder met de volgende stap.
-
Bekijk de opdrachtuitvoer /nasmcd/getreason -e om de Slic-codes van de datamover te bepalen.
[nasadmin@xxxxx~]$ /nasmcd/getreason -e 10 - slot_0 primary control station 5 - slot_2 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613) 5 - slot_3 contacted(Post Code = 0x61 ; Mid Code = 0x80 ; Blade Code = 0x2c ; Slic Code = 132613)
-
Bewerk het bestand /nas/server/slot_x/device met VI Editor en voeg de juiste waarde toe aan de regel "slicsignature validate=". Mogelijk moet u ook de eerste tekst "slicsignature validate=" toevoegen.
[nasadmin@xxxxx ~]$ cat /nas/server/slot_3/device device isa isa-0 device pci pci-0 dskdumpconfig full slot=3 pciautoconfig el3config tier2-aui slicsignature validate=132613 < --- Edit the last line in file.
-
Voer de nas_checkup opnieuw uit om te controleren of de fouten zijn opgelost. U kunt "nas_checkup -rerun" uitvoeren om alleen de eerdere fouten of fouten te controleren.
Escaleer dit probleem indien nodig via uw serviceprovider en geef de nas_checkup output in de escalatie.