VxRail: Two-Node Cluster Deployment Fails to Assign Storage Policy
Resumen: The deployment cannot assign a storage policy because the VMkernel interface vmk0 carries an extra vSAN Witness tag; only the management network tag should be present, causing the failure. ...
Este artículo se aplica a
Este artículo no se aplica a
Este artículo no está vinculado a ningún producto específico.
No se identifican todas las versiones del producto en este artículo.
Síntomas
During a two‑node VxRail cluster deployment the process cannot assign the storage policy to the virtual machine. The VxRail Manager reports that it cannot create the required three fault domains.
Symptoms observed:
- Deployment stops with a failure to assign the storage policy.
- Management network interface vmk0 shows an unexpected vSAN Witness tag.
Causa
-There is vSAN Witness Tag enabled on the management Network as well.
- VMK0 should only have on Tag which is the Management Network:
Resolución
- Run the command below to check for the tags associated with VMK0:
esxcli network ip interface tag get -i vmk0 - Run the command below to remove the VSAN witness tag:
esxcli network ip interface tag remove -i vmk0 -t VSANWITNESS - Retry the configuration again now.
- If the issue remains, refresh the VMK0 connection and retry the configuration again:
esxcli network ip interface set -e false -i vmk0
esxcli network ip interface set -e true -i vmk0
Productos afectados
VxRail, VxRail Appliance Series, VxRail SoftwarePropiedades del artículo
Número del artículo: 000221852
Tipo de artículo: Solution
Última modificación: 22 sept 2026
Versión: 4
Encuentre respuestas a sus preguntas de otros usuarios de Dell
Servicios de soporte
Compruebe si el dispositivo está cubierto por los servicios de soporte.