NetWorker: Library volume pools 'refreshing'
Résumé: Cosmetic code defect which prevents unlabeled volumes from being correctly presented as such.
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
- Library contains cartridges which correctly show barcodes along with corresponding volume fields, but pool stays perpetually in 'refreshing' state
- Reset / Inventory does not correct the volumes
- Barcode Matching set for library
Cause
Code defect - NWREE-29885 which is under investigation.
Résolution
Generally the volumes found in this state are not being correctly presented as being 'unlabeled' / not in media database, and are safe to relabel. To check the volume label first:
- Confirm the volume is not in the media database with mminfo:
mminfo -a volid,pool -q barcode=barcode_in_NMC - Check the soft label by loading the tape without mounting it and performing a diagnostic check:
nsrmm -pv -f "name_of_device_in_NetWorker"
Once satisfied the volume has no viable data, relabel normally.
Note that even if there is a NetWorker label on the volume, NetWorker will prompt to confirm you wish to overwrite (provided the override tickbox is not selected), if the volume is labeled and the record does not reflect it being expired.
Produits concernés
NetWorkerPropriétés de l’article
Numéro d’article: 000492290
Type d’article: Solution
Dernière modification: 30 Jul 2026
Version: 1
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.