Data Domain: The Storage Processor has Failed - Coin Cell Battery failed (CMOS Battery)
Résumé: This article addresses the failure of the CMOS or system battery within a Data Domain. Alert Posted (EVT-ENVIRONMENT-00032) on Data Domain systems indicate the Storage Processor (SP) has failed. Additional information within the posted alert notification indicates the cause as "Coin cell battery failed." ...
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
Data Domain system posts an Alert notification to indicate the Storage Processor (SP) has failed.
"Additional Information" within the Posted alert states the cause is a failed coin-cell battery.
Affected Systems:
Unexpected system behavior may be encountered until the battery is replaced.
"Additional Information" within the Posted alert states the cause is a failed coin-cell battery.
NOTE: This article is for the failed coin-cell (aka CMOS or System) battery. Other failures for the same Event ID (ENVIRONMENT-00032) are addressed in article Data Domain: Alert: The storage processor has failed.
Affected Systems:
- All Data Domain Systems
- All DDOS versions
- Alert Notification:
Event Id: EVT-ENVIRONMENT-00032 Event Message: The storage processor has failed Object: Enclosure=1 Additional Information: Cause=Coin cell battery failed
- BIOS log (within latest Auto-Support or Support Bundle)
Example: Coin-Cell entry shows <= 2.2 voltage (on legacy Data Domain systems)
Voltage CoinCell_Voltage | Lower Critical going low | Asserted | Reading 2.20
- MESSAGES log (within latest Auto-Support or Support Bundle)
Multiple entries for SP failure, as below:
platmon: CRITICAL: The storage processor has failed. Enclosure=1 Cause="Coin cell battery failed"
- On PowerEdge-based Systems (PowerProtect Data Domain), the failure is captured in iDRAC TSR Logs
The CMOS battery has failed
Unexpected system behavior may be encountered until the battery is replaced.
Cause
If the battery voltage drops below the threshold, then the Alert (EVT-ENVIRONMENT-00032) is posted. The System Battery (a.k.a Coin cell, CMOS, or RTC) has a minimum voltage threshold to function as expected. Any reading below the given threshold is considered a battery failure, and it should be replaced immediately.
For legacy Data Domain systems, the voltage must be > 2.2 voltage.
For PowerProtect Data Domain systems, the voltage must be > 3v.
For legacy Data Domain systems, the voltage must be > 2.2 voltage.
For PowerProtect Data Domain systems, the voltage must be > 3v.
Résolution
For ALL Legacy Data Domain systems:
- Dell Technologies does not stock system batteries.
- A replacement SP must be dispatched.
- PowerProtect (DD3300, DD6900, DD9400, DD9900, or newer models)
- A replacement system battery must be dispatched.
Informations supplémentaires
For other 'Storage Processor has failed' cases, see article Data Domain: Alert: The storage processor has failed.
Produits concernés
Data Domain, PowerProtect Data Protection Appliance, Data Domain, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwarePropriétés de l’article
Numéro d’article: 000053738
Type d’article: Solution
Dernière modification: 01 mai 2024
Version: 5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.