PowerFlex: Unable to Exit Maintenance Mode Due to Failed Capacity
Résumé: Failed disks on two SDS nodes created failed capacity, causing the to stay in EXIT_MAINTENANCE_IN_PROGRESS and block exiting maintenance mode until the hardware is replaced and rebuilt. ...
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
Lost two disks on separate SDSs simultaneously that caused data failed. Multiple attempts to exit maintenance mode fail.
server@node-2-2 ~ $ scli --clear_sds_device_error --sds_ip 1X.2X.1X.1 --device_id 2c2zz93a01f30000 --clear_all Successfully cleared all SDS with IP 1X.2X.1X.1 (port 7072) devices server@node-2-2 ~ $ scli --query_all_sds | grep 1X.1X.1X.1 SDS ID: ce87bbdc000001cd Name: sds1X.1X.1X.1 State: Connected, Joined IP: 1X.1X.1X.1 Port: 7072 EXIT_MAINTENANCE_IN_PROGRESS Version: 2.0.5014 server@node-2-2 ~ $ scli --exit_maintenance_mode --sds_ip 1X.1X.1X.1 --protection_domain_name PD3 --force_failed_device_id 2c2zz92401cb0000 Exit Maintenance Mode Results: SDS sds1X.9.1X.1: The specified SDS is in a process of exiting maintenance-mode. server@node-2-2 ~ $ scli --exit_maintenance_mode --sds_ip 1X.1X.1X.1 --protection_domain_name PD3 --force_failed_sds Exit Maintenance Mode Results: SDS sds10.11.10.1: The specified SDS is in a process of exiting maintenance-mode. Error: MDM failed command. Status: The specified SDS is in a process of exiting maintenance-mode.
If you look at scli --query_all, you see we are.
SDS Summary:
Total 276 SDS Nodes
276 SDS nodes have membership state 'Joined'
276 SDS nodes have connection state 'Connected'
1 SDS nodes have maintenance state 'Exiting-Maintenance-Mode'
469.6 TB (480836 GB) total capacity
357.5 TB (366093 GB) unused capacity
0 Bytes snapshots capacity
45.1 TB (46192 GB) in-use capacity
0 Bytes thin capacity
45.1 TB (46168 GB) protected capacity
24.0 GB (24571 MB) failed capacity
0 Bytes degraded-failed capacity
0 Bytes degraded-healthy capacity
3.5 TB (3556 GB) unreachable-unused capacity
Cause
The system will not allow exiting Maintenance mode while there is failed capacity to protect the data.
Résolution
- Validate all Storage Nodes are powered on. If any are down:
- Resolve hardware issues (e.g., PSU, motherboard, cabling).
- Power on the node manually or via remote management.
- Clear the device(s) error from PowerFlex.
- Exit Maintenance Mode if any nodes are in MM:
Produits concernés