PowerFlex: Kan ikke avslutte vedlikeholdsmodus
Résumé: PowerFlex sitter fast i EXIT_MAINTENANCE_IN_PROGRESS.
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
Mistet to disker på separate SDS-er samtidig som forårsaket at data mislyktes. Flere forsøk på å avslutte vedlikeholdsmodus mislykkes.
server@node-2-2 ~ $ scli --clear_sds_device_error --sds_ip 1X.2X.1X.1 --device_id 2c2zz93a01f30000 --clear_all Successfully cleared all SDS with IP 1X.2X.1X.1 (port 7072) devices server@node-2-2 ~ $ scli --query_all_sds | grep 1X.1X.1X.1 SDS ID: ce87bbdc000001cd Name: sds1X.1X.1X.1 State: Connected, Joined IP: 1X.1X.1X.1 Port: 7072 EXIT_MAINTENANCE_IN_PROGRESS Version: 2.0.5014 server@node-2-2 ~ $ scli --exit_maintenance_mode --sds_ip 1X.1X.1X.1 --protection_domain_name PD3 --force_failed_device_id 2c2zz92401cb0000 Exit Maintenance Mode Results: SDS sds1X.9.1X.1: The specified SDS is in a process of exiting maintenance-mode. server@node-2-2 ~ $ scli --exit_maintenance_mode --sds_ip 1X.1X.1X.1 --protection_domain_name PD3 --force_failed_sds Exit Maintenance Mode Results: SDS sds10.11.10.1: The specified SDS is in a process of exiting maintenance-mode. Error: MDM failed command. Status: The specified SDS is in a process of exiting maintenance-mode.
Hvis du ser på scli --query_all, Du ser vi er.
SDS Summary:
Total 276 SDS Nodes
276 SDS nodes have membership state 'Joined'
276 SDS nodes have connection state 'Connected'
1 SDS nodes have maintenance state 'Exiting-Maintenance-Mode'
469.6 TB (480836 GB) total capacity
357.5 TB (366093 GB) unused capacity
0 Bytes snapshots capacity
45.1 TB (46192 GB) in-use capacity
0 Bytes thin capacity
45.1 TB (46168 GB) protected capacity
24.0 GB (24571 MB) failed capacity
0 Bytes degraded-failed capacity
0 Bytes degraded-healthy capacity
3.5 TB (3556 GB) unreachable-unused capacity
Cause
Systemet tillater ikke avslutning av vedlikeholdsmodus når kapasiteten for å beskytte dataene svikter.
Résolution
Brukeren må løse den defekte kapasiteten, erstatte HW som har sviktet og tillate gjenoppbygging
Produits concernés
PowerFlex rack, ScaleIOPropriétés de l’article
Numéro d’article: 000171816
Type d’article: Solution
Dernière modification: 25 août 2026
Version: 5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support