DSA-2025-339: Security Update for Dell Avamar Data Store Gen5A Multiple Third-Party Component Vulnerabilities

Résumé: Dell Avamar Data Store Gen5A remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Impact

Critical

Détails

Third-party Component CVEs More Information
Dell PowerEdge Server BIOS CVE-2024-38796, CVE-2024-28956, CVE-2024-45332, CVE-2024-48012, CVE-2026-26945  DSA-2025-038, DSA-2025-041, DSA-2025-156, DSA-2025-046, DSA-2026-113
Integrated Dell Remote Access Controller (iDRAC) CVE-2025-26466, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50602, CVE-2024-2961, CVE-2023-6780, CVE-2024-52533, CVE-2023-52340, CVE-2024-42154, CVE-2026-26948 DSA-2025-145. DSA-2025-146, DSA-2024-460, DSA-2026-113

Dell Technologies recommande à tous les clients de prendre en compte à la fois le score de base CVSS et les scores temporels et environnementaux pertinents qui peuvent avoir un impact sur la gravité potentielle associée à une faille de sécurité donnée.

Produits concernés et mesure corrective

Product Software/Firmware Affected Versions Remediated Versions Link
Avamar Data Store Gen5A Dell PowerEdge Server BIOS Versions prior to 2.24.0 Version 2.24.0 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)
Avamar Data Store Gen5A Integrated Dell Remote Access Controller (iDRAC) Versions prior to 7.00.00.181 Version 7.00.00.181 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)

 

Product Software/Firmware Affected Versions Remediated Versions Link
Avamar Data Store Gen5A Dell PowerEdge Server BIOS Versions prior to 2.24.0 Version 2.24.0 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)
Avamar Data Store Gen5A Integrated Dell Remote Access Controller (iDRAC) Versions prior to 7.00.00.181 Version 7.00.00.181 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)

 

Notes:

Known Issue:

  • Upgrading directly to the August 2025 firmware, which includes BIOS 2.24.0, may fail on systems running BIOS versions prior to 2.12.2, due to compatibility constraints.

  

Required Action:

  • To verify the BIOS version, run the following command in the Avamar console as an admin/root user:
     omreport system version
  • If the BIOS version is earlier than 2.12.2 contact Dell Customer Support to apply the September 2021 firmware block (AVP: Gen5aSep2021Blk338753.avp) before installing the August 2025 firmware.

Solutions de contournement et mesures d’atténuation

None

Historique des révisions

RevisionDateDescription
1.02025-09-01Initial Release
2.02025-10-06Replaced the NVD generic search link with the PowerEdge and iDrac advisories
3.02025-10-22Major update to include CVE-2024-48012
4.02025-12-30Updated 'Additional Information' section
5.02026-05-06Major update to include CVE-2026-26945
6.02026-05-07Major update to include CVE-2026-26948 

Informations connexes

Produits concernés

Avamar, Avamar Data Store, Avamar Data Store Gen5A, Avamar Server
Propriétés de l’article
Numéro d’article: 000362542
Type d’article: Dell Security Advisory
Dernière modification: 07 mai 2026
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.