ECS: getrackinfo changes post 3.2.2

Résumé: getrackinfo changes post 3.2.2 upgrade.

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Instructions

After upgrade to 3.2.2.0 there is a change in the getrackinfo display for BMC/RMM addresses.


ECS Generation Gen 1 and Gen 2 - BMC (channel 1) and RMM (channel 3)
ECS Generation Gen 3 - BMC (channel 1)

Prior to upgrade:

Command:

# getrackinfo

Example:

Node private      Node              Public                                  RMM
Ip Address        Id       Status   Mac                 Ip Address          Mac                 Ip Address          Node Name
===============   ======   ======   =================   =================   =================   =================   =========
192.168.219.1     1        MA       00:1e:67:fd:8e:9e   xxx.xxx.xxx.xxx     00:1e:67:dd:c4:33   xxx.xxx.xxx.xxx      provo-red
192.168.219.2     2        SA       00:1e:67:fd:7d:86   xxx.xxx.xxx.xxx     00:1e:67:df:fe:87   xxx.xxx.xxx.xxx      sandy-red
192.168.219.3     3        SA       00:1e:67:fd:88:96   xxx.xxx.xxx.xxx     00:1e:67:d6:11:63   xxx.xxx.xxx.xxx      orem-red
192.168.219.4     4        SA       00:1e:67:fd:7f:b6   xxx.xxx.xxx.xxx     00:1e:67:df:f6:53   xxx.xxx.xxx.xxx      ogden-red

Post upgrade:

Node private      Node              Public                                  BMC
Ip Address        Id       Status   Mac                 Ip Address          Mac                 Ip Address          Node Name
===============   ======   ======   =================   =================   =================   =================   =========
192.168.219.1     1        MA       00:1e:67:fd:8e:9e   xxx.xxx.xxx.xxx     00:1e:67:dd:c4:33   xxx.xxx.xxx.xxx      provo-red
192.168.219.2     2        SA       00:1e:67:fd:7d:86   xxx.xxx.xxx.xxx     00:1e:67:df:fe:87   xxx.xxx.xxx.xxx      sandy-red
192.168.219.3     3        SA       00:1e:67:fd:88:96   xxx.xxx.xxx.xxx     00:1e:67:d6:11:63   xxx.xxx.xxx.xxx      orem-red
192.168.219.4     4        SA       00:1e:67:fd:7f:b6   xxx.xxx.xxx.xxx     00:1e:67:df:f6:53   xxx.xxx.xxx.xxx      ogden-red

ECS Gen 1 and Gen 2 the IP configuration showed above is channel 3 which is RMM (Public BMC).
ECS Gen 3 the IP configuration shown here is channel 1 which is BMC (Internal BMC).

There is a terminology change after 3.2.2.0 to try to standardize the terminology to BMC for all out of band mgmt interfaces (iDRAC).

Produits concernés

Elastic Cloud Storage

Produits

ECS Appliance, Elastic Cloud Storage
Propriétés de l’article
Numéro d’article: 000009321
Type d’article: How To
Dernière modification: 23 avr. 2025
Version:  7
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.