PowerFlex 5.1: Export Compliance PDF report generation timeout

Résumé: PDF compliance report generation fails with a timeout and an ArrayIndexOutOfBoundsException error in PowerFlex Manager 5.1.0.0. To restore PDF functionality, PFMP must be upgraded.

Cet article concerne Cet article ne concerne pas Cet article n’est associé à aucun produit spécifique. Toutes les versions du produit ne sont pas identifiées dans cet article.

Symptômes

When attempting to perform the Export Reports function, PowerFlex Manager hangs when attempting to create a PDF compliance report. After clicking Export, the UI remains on the Loading Reports screen and eventually times out.

The following error appears in the asmmanager logs:

ArrayIndexOutOfBoundsException: Index 3 out of bounds for length 3
 

Relevant log excerpt:

2026-06-24 12:15:53,974 [JobMgrQuartzScheduler_Worker-25] (FirmwareCompliancePDFOutput.java:99) [WARN] Exception caught creating PDF file for resources java.lang.ArrayIndexOutOfBoundsException: Index 3 out of bounds for length 3 at org.apache.commons.csv.CSVRecord.get(CSVRecord.java:81) at be.quodlibet.boxable.datatable.DataTable.addCsvToTable(DataTable.java:290) at be.quodlibet.boxable.datatable.DataTable.addListToTable(DataTable.java:204) at com.dell.asm.asmcore.asmmanager.util.report.FirmwareCompliancePDFOutput.writeModifiedComplianceSection(FirmwareCompliancePDFOutput.java:385) ...
 

loading reports

Impact

Users are unable to export compliance information as PDF, which may delay reporting activities but does not affect core storage operations.

Cause

A limitation in the PDF report generation process can cause failures when certain component names contain special characters. Under specific conditions, these characters may interfere with how report data is processed during PDF creation, preventing the report from being generated successfully.

Résolution

There is currently No Workaround Available. Upgrade PowerFlex Manager to 5.2, where PDF export will function correctly.

 

Impacted Versions

 PFMP 5.1

Fixed In Version

PFMP 5.2

Produits

PowerFlex rack, ScaleIO
Propriétés de l’article
Numéro d’article: 000502475
Type d’article: Solution
Dernière modification: 24 Aug 2026
Version:  1
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.