Isilon: Node Firmware updates immediately error on Generation 6 nodes with a missing/failed M2 Vault Card
Résumé: Isilon: Node Firmware updates immediately error on Generation 6 nodes with a missing/failed M2 Vault Card
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
Generation 6 nodes require use of an M.2 Vault Card in each node to perform node firmware updates. If the M.2 Vault Card is missing or has failed, attempts to perform node firmware updates on those nodes will encounter an error.
In addition to errors in the upgrade view, the log file, /var/log/isi_firmware.log, on the node where the error was encountered will have a line which includes "no such object ada0" similar to the following:
2020-01-01 04:54:25,169 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,170 INFO [11111] : FW action: toggle_debug: off
2020-01-01 04:54:25,241 INFO [11111] : FW action: Updating Node 1
2020-01-01 04:54:25,263 INFO [11111] : Updating device EPssp_infinity
2020-01-01 04:54:25,263 INFO [22222] : <rpc> EPssp_infinity(EPssp_infinity): version=02.50 target=02.81
2020-01-01 04:54:25,264 INFO [11111] : Updating Firmware EPssp_infinity - old: 02.50 new : 02.81
2020-01-01 04:54:25,526 ERROR [11111] : Node 1: 'no such object ada0'
2020-01-01 04:54:25,565 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,565 INFO [11111] : FW action: toggle_debug: offCause
missing vault card
Résolution
When encountered, the M.2 Vault Card on the node should be replaced.
Informations supplémentaires
The Isilon On-Cluster Analysis health check script includes a check to identify when the M.2 Vault Card is missing or has exceeded it's SMART status threshold and may report results similar to the following:
Vault Card FAIL FAIL: The vault card located at ada0 in the following Generation 6 nodes are not reporting in the output of camcontrol devlist: 1 FAIL: The vault card located at ada0 in the following Generation 6 nodes are reporting SMART status is threshold exceeded: 1
To run only the check for the Vault Card, use the following additional argument when running the Isilon On-Cluster Analysis tool: --run=checkVaultCard
Produits concernés
Isilon Gen6Produits
Isilon Gen6Propriétés de l’article
Numéro d’article: 000082048
Type d’article: Solution
Dernière modification: 18 avr. 2026
Version: 5
Trouvez des réponses à vos questions auprès d’autres utilisateurs Dell
Services de support
Vérifiez si votre appareil est couvert par les services de support.