VxRail: Event Code VXR508CTL139
Résumé: Event VXR508CTL139 indicates: The storage controller arg1 is unable to communicate to the BMC because of arg2 Error. iDRAC management for this device is unavailable.
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
iDRAC event CTL139 occurs and YELLOW alarm VXR508CTL139 presents in vCenter portal.
Cause
The storage controller is unable to communicate to the BMC because of the reason identified in the message. iDRAC management for this device is unavailable.
Résolution
Run the following RACADM command at the Command Line Interface (CLI) and retry the operation: racadm racreset
For more information about RACADM commands of iDRAC, see the latest version of "iDRAC with Lifecycle Controller RACADM CLI Guide" available on the support site.
Produits concernés
VxRail, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N, VxRail E665, VxRail E665F
, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760
...