DSA-2024-089: Security Update for Dell iDRAC8 local RACADM Vulnerability

Riepilogo: Dell iDRAC8 remediation is available for local RACADM that could be exploited by authenticated malicious users to compromise the affected system.

Questo articolo si applica a Questo articolo non si applica a Questo articolo non è legato a un prodotto specifico. Non tutte le versioni del prodotto sono identificate in questo articolo.

Impatto

High

Dettagli

Proprietary Code CVEs Description CVSS Base Score CVSS Vector String
CVE-2024-25951 A command injection vulnerability exists in local RACADM. A malicious authenticated user could gain control of the underlying operating system. 8.0 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HThis hyperlink is taking you to a website outside of Dell Technologies. ​​​​​
Proprietary Code CVEs Description CVSS Base Score CVSS Vector String
CVE-2024-25951 A command injection vulnerability exists in local RACADM. A malicious authenticated user could gain control of the underlying operating system. 8.0 CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HThis hyperlink is taking you to a website outside of Dell Technologies. ​​​​​
Dell Technologies raccomanda a tutti i clienti di prendere in considerazione sia il punteggio base CVSS, sia ogni eventuale punteggio temporale o ambientale che possa avere effetti sul livello di gravità potenziale associato a una specifica vulnerabilità di sicurezza.

Prodotti interessati e correzione

CVEs Addressed Product Software/Firmware Affected Versions Remediated Versions Link
CVE-2024-25951 iDRAC8 iDRAC8 Versions prior to 2.85.85.85 version 2.85.85.85 or later iDRAC8 2.85.85.8
CVEs Addressed Product Software/Firmware Affected Versions Remediated Versions Link
CVE-2024-25951 iDRAC8 iDRAC8 Versions prior to 2.85.85.85 version 2.85.85.85 or later iDRAC8 2.85.85.8

Soluzioni alternative e mitigazioni

None

Cronologia delle revisioni

RevisionDateDescription
1.02024-02-29Initial Release
2.02024-06-13Updated for enhanced presentation with no changes to content
3.02024-06-22Updated for enhanced presentation with no changes to content

Ringraziamenti

Dell Technologies would like to thank NCC Group for reporting this issue.

Informazioni correlate

Prodotti interessati

Dell DL1300, Dell DL4300, Dell DR4300, Dell DR4300e, Dell DR6300, Dell XC430 Hyper-converged Appliance, Dell XC430 Xpress Hyper-converged Appliance, Dell Storage NX3230, Dell Storage NX3330, Dell Storage NX430

Prodotti

DSS 2500, DSS 7500, DSS 1500, DSS 1510, Dell XC630 Hyper-converged Appliance, Dell XC6320 Hyper-converged Appliance, Dell XC730 Hyper-converged Appliance, Dell XC730XD Hyper-converged Appliance, OEMR R230, OEMR R330, OEMR R430, OEMR R530, OEMR R630 , OEMR R730, OEMR R730xd, OEMR R830, OEMR R930, OEMR T130, OEMR T330, OEMR T430, OEMR T630, R7910 XL, PowerEdge C4130, PowerEdge c6320, PowerEdge c6320p, Poweredge FC430, Poweredge FC630, Poweredge FC830, PowerEdge FD332, PowerEdge M630, PowerEdge M630 (for PE VRTX), PowerEdge M830, PowerEdge M830 (for PE VRTX), PowerEdge R230, PowerEdge R330, PowerEdge R430, PowerEdge R530, PowerEdge R530xd, PowerEdge R630, PowerEdge R730, PowerEdge R730xd, PowerEdge R830, PowerEdge R930, PowerEdge T130, PowerEdge T330, PowerEdge T430, PowerEdge T630, Precision Rack 7910, SD630-S ...
Proprietà dell'articolo